High duty cycle due to additional fan function. 328 | ELECTRODE WELDING SYSTEMS COMMON FEATURES .. "Smart intelligence": state-of-the-art processor control for easy operation and ideal welding results .. Automatic hot start for perfect ignition of electric arc .. Arc-force regulation for even welding results .. Anti-stick mechanism prevents electrodes from sticking .. Switchable lift arc function for x-ray safe TIG welding with an optional TIG torch .. Ergonomic and protected control elements ..
Si l’on vis vers l’exterieur, on diminue la quantite qui circule. x Lors du reglage, il faut mettre l’appareil en service et l’interrupteur du chalumeau doit etre pousse pour pouvoir ouvrir la vanne magnetique. Pour eviter de consommer trop d’electrode, on fait pivoter lateralement le ressort a lames de l’avancement d’electrode. Les operations et reparations sur les detendeurs sont interdits, a cause des dangers que representent ces operations. Les detendeurs qui sont defectueux doivent etre exp
x Neighbouring workplaces are to be screened off to provide protection against radiation. x When welding inside rooms and buildings sufficient ventilation must be ensured. A A Fire Danger! The arc temperature is approx. 2400 °C. Before starting to weld observe the following information: x Remove all combustible materials and objects within a radius of 5 m from the welding point. x Materials that can not be removed within a 5 m radius must be protected by covering with sheet metal, wet cloths etc
B. Work Practice Controls: involve adjustments in the way a task is performed, as well as the periodic inspection and maintenance of engineering control equipment. In many cases, work practice controls complement engineering controls in providing employee protection. C. Personal Protection Equipment: When engineering and work practice controls cannot reduce employee exposure to within the PEL, employers must provide respirators. OSHA’s Methods of Compliance states that: "If feasible engineering
It is configured for for welding mild steel using the self shielded, Innershield electrode process (FCAW) as delivered from the factory. It can be converted for the GMAW, single pass, process which requires a supply of shielding gas and the K610-2 MIG Conversion Kit. The WELD-PAK operates on208/230 VAC input power. LAS CHISPAS DEL ARCO pueden quemar los ojos y la piel. • Utilice proteccion para ojos, orejas y cuerpo. DESCRIPCION GENERAL La WELD-PAK es una fuente de poder/alimentador de alam- bre
Vantage 500 DEUTZ C-1 ACCESSORIES C-1 OPTIONAL FIELD INSTALLED ACCESSORIES K704 ACCESSORY SET - Includes 35 feet (10 m) of electrode cable and 30 feet (9 m) of work cable, headshield, work clamp and electrode holder. Cable is rated at 500 amps, 60% duty cycle. K767-2 FOUR WHEELED STEERABLE YARD TRAILER - For in plant and yard towing. K802N POWER PLUG KIT - Provides four 120V plugs rated at 20 amps each and one dual voltage, full KVA plug rated at 120/240V, 50 amps. 120V plug may not be compatibl
Clair Avenue Cleveland, OH 44117-1199 (216) 481-8100 Product Type: Cored Electrode Classification: None SECTION II - HAZARDOUS MATERIAL (1) I M P O R T A N T ! This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal use of this product are covered by Section V; see it for industrial hygiene information. CAS Number shown is representative for the ingredients listed. All ingredients listed may not be present in all size
carburation, ignition, timing and valve or port timing) without the addition of any major hardware. Adjusting Carburetor The carburetor is set at the factory to provide an optimum fuel-air mixture under most operating conditions. Idling and part-load emissions are minimized by limiting the idle mixture. Standard setting : Check the air filter and clean or replace it if necessary. : Check the spark arresting screen and clean or replace it if necessary. : Warm up the engine. : Carefully screw the
5 year warranty on main transformer .. CE-inspected Comparative device characteristics Mains voltage 230/400 V 230/400 V Maximum power input at 400 V 6,7 kVA 6,7 kVA Setting range (400 V) 60 - 170 A 60 - 170 A Regulation 6 levels each 6 levels each Weldable wire 0,6 - 0,8 mm 0,6 - 0,8 mm Weldable material thickness 0,5 - 6 mm 0,5 - 6 mm Maximum duty cycle at 25 °C 30 % 30 % Maximum duty cycle at 40 °C 20 % 20 % 100% duty cycle at 25 °C 90 A 90 A 100% duty cycle at 40 °C 60 A 60 A Fuse protection
In order to see the current sensitivity setting, momentarily press the Sensitivity button. To select another setting, press the Sensitivity button again while the LED is flashing, and continue to press until the LED shows the desired setting. Position 1 Least sensitive setting. Used if there is interference from other welders’ arcs in the vicinity. Position 2 Normal position. Used for most types of welding indoors and outdoors. Position 3 Position for welding with low current or with stable weld