Log:
Évaluations - 2, GPA: 5 ( )

Instructions A&D, Modèle ML-50

Fabricant : A&D
Taille : 1.2 mb
Nom Fichier : ms_mx_mf_ml.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


When the halogen lamp has cooled down, the next measurement can be started. If necessary, change the drying time and temperature. When a measurement is started and the time passes one hour, the maximum temperature is automatically regulated to 160°C for safety. Operation to Stop Measurement During measurement, the STOP key is always effective. If there is an error or danger, press the STOP key. 2.3. After Use and Maintaining the Analyzer Put dust cover on the analyzer after it is cool. Clean the glass-housing carefully. Clean fingerprints from the halogen lamp to keep its life. Refer to "14.2.Replacement of the Halogen Lamp". Avoid mechanical shock to the analyzer. Do not disassemble the analyzer. Protect the analyzer from excessive dust. Use the packing box (special container) to move the analyzer. Clean the analyzer with a lint free cloth that is moistened with warm water and a mild detergent. Do not use organic solvents to clean the analyzer. Do not disassemble or remodel the analyzer. Glass-housing Halogen lamp Glass housing Screw Screw 8 MS-70 / MX-50 / MF-50 / ML-50 3. Outline and Features 3. Outline and Features The moisture analyzer was designed using a super hybrid sensor (S.H.S.) adopted in an analytical balance. Therefore, the results are more precise and get greater repeatability. An analyzer using the S.H.S. has high sensitivity, needs only a sample quantity of a few grams, and the analysis time becomes shorter. A 400W halogen lamp is used as the heating source and the temperature on the sample pan can reach 200°C within two minutes. There are five analysis modes. Standard mode .....The moisture content can be obtained with settings of the drying temperature and accuracy. Quick mode ........... Sample is heated up for approximately three minutes at 200°C so that analysis time becomes shorter. The moisture content can be obtained with settings of the drying temperature and accuracy. Automatic mode.....When the change of moisture content per minute is less than the preset termination value, the measurement is automatically stopped and the result is obtained. Timer mode.............The sample is dried for a preset time and the result is obtained. Manual mode..........This mode can stop the measurement by key operation and the result is decided. The heating patterns can be used for analysis mode without using the quick mode. (For ML-50, standard drying and quick drying can be used only) Standard drying......Maintains a constant drying temperature. Ramp drying ...........Increases the drying temperature gently. Step drying..............Uses multiple steps of the drying temperature. Quick drying ...........Heats up to 200°C for few minutes and uses a constant drying temperature. The analyzer can store and recall proper individual settings for each sample using a program number (PROG No.). Maximum program number MS-70 / MX-50 MF-50 ML-50 20 sets 10 sets 5 sets The data memory function can store the results and output all of them at one time. Maximum number of storable results MS-70 / MX-50 MF-50 ML-50 100 50 30 The software, "WinCT-Moisture", a standard accessory for the MS-70 and MX-50, has a function that can make a graph of the change of moisture content in realtime and has an optimum temperature search program that judges heating at an appropriate temperature setting. The software, " WinCT", a standard accessory for the MF-50, is communication software for transmitting data to a computer using Microsoft Windows. MS-70 / MX-50 / MF-50 / ML-50 9 The analyzer is equipped with a serial interface as standard. It can be connected to a printer or computer. The analyzer can calibrate the weighing sensor (Use special mass.) and drying temperature (Use temperature calibrator for MS-70 and MX-50 except MF-50 and ML-50). The analyzer can output the data required at GLP, GMP and ISO at the end of the calibration. The analyzer has a self check function that can detect function errors. The analyzer displays the current change of moisture content per minute [%/ min] in real-time. It can be used for the reference to find the analyzing mode. The sample pans can be used repeatedly. The sample pans and the disposable aluminum foil pans are included in the standard accessories. There is a test sample that is used to check the moisture accuracy. (The test sample is a part of the standard accessories except for the ML-50) The glass fiber sheets can be used for quick and precise measurement of a liquid sample. (The glass fiber sheets are a part of the standard accessories except for the ML-50) A reference card is built into the bottom of the analyzer. Principle and UseThe moisture analyzer, based on the principle of thermogravimetric analysis, dries a sample using a halogen lamp and obtains the moisture content in % and other results by the difference between the wet weight and dry weight. 10 MS-70 / MX-50 / MF-50 / ML-50 4. Packing List and Names of each part 4. Packing List and Names of each part Keep the packing box t...

Ce manuel est également adapté pour les modèles :
Thermostats - MF-50 (1.2 mb)
Thermostats - MF-50 (1.2 mb)
Thermostats - MS-70 (1.2 mb)
Thermostats - MX-50 (1.2 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories