Instructions Aube Technologies, Modèle TH111GFCI-P

Fabricant : Aube Technologies
Taille : 219.05 kb
Nom Fichier : TH111-GFCI-P-120.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


TO SET TIME AND DAY Press on DAY, HOUR and MIN buttons to adjust time and day. TO RECORD THE (COMFORT) SETPOINT TEMPERATURE Select chosen setpoint temperature by using or button. Press on button (2 to 3 seconds) until icon appears on display. TO RECORD THE (ECONOMY) SETPOINT TEMPERATURE Select chosen setpoint temperature by using or button. Press on button (2 to 3 seconds) until icon appears on display . CHECKING GROUND FAULT CIRCUIT INTERRUPTER (GFCI) Adjust the setpoint temperature until heating indicator ( ) appears on display. Press on TEST button. The test is conclusive if the warning light (GFI) on thermostat is ON and power to the load is cut-off ( remain on display though). If these events do not occur, check the installation. Press on RESET button to reset the GFCI. OPERATING MODES To select an operating mode, use MODE button. AUTO: Runs the program. or shows temperature setting and can override temporarily your programming up to the next program MAN: Maintains the selected temperature. or changes the temperature setting. Power-up When power is applied for the first time, the display must show the time 00:00, the floor temperature and the manual mode icon ( ). Other information might show up on the display if installation is defective or does not comply with the instructions. The warning light (GFI) must be off. The message L0 or HI will appear on the display if the temperature sensor is defective or the temperature is below 0 °C (32 °F) or higher than 60 °C (140 °F). Also, the heating indicator will be present on display and the relay will be closed (current going in the load). Checking ground fault circuit interrupter (GFCI) Adjust the setpoint temperature until heating indicator ( ) appears on display. Press on TEST button. The test is conclusive if the warning light (GFI) on the thermostat is ON and power to the load is cut-off. If these events do not occur, check the installation. Press on RESET button to reset the GFCI. If the GFCI test fails: Check the load wires. The thermostat must be in heating mode to carry out the test (heating indicator ON). The GFCI test should be carried out monthly. If the test fails, cut off the electric power to the heating system and call customer service or return the thermostat to your supplier for verification. If the warning light comes on during normal operation, cut off power to the heating system and have an electrician verify the installation. MODEL TH111GFCI-P (120 VAC) INSTALLATION This thermostat is designed to control floor electric heating systems. The resistive load must not exceed 2000 watts (NI) @ 120 VAC (16.7 A). The thermostat is equipped with a ground fault circuit interrupter (GFCI) and therefore the isolation of the line and load are required for operation. The polarity of line connection (line and neutral) must be respected. During a ground fault, only the current in the black wire (line) of the load will be cut-off. Connect thermostat as shown on diagram. Electricians or experienced technicians should install the thermostat. This thermostat is designed to be used with a circuit breaker. PARTS INCLUDED - One (1) TH111 GFCI-P (120 VAC) thermostat - Two (2) 6-32 screws - Four (4) solderless connectors (for copper wire) - One (1) Temperature sensor with a 15 foot extension TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Keep air vents of the thermostat clean and free from obstructions. 1) Connecting wires and mounting thermostat Connect the rear thermostat wires to the power supply and to the load using solderless connectors for copper wires. See schematic diagram. u u u u u u Push the excess wire back into the electrical box to prevent interference with the thermostat. Secure the thermostat using two (2) 6-32 screws . Once the thermostat is properly installed, return power to heating system. NOTE : All cables and connections must conform to the local electrical code. WARNING : Special CO/ALR solderless connectors must be used when connecting with aluminum conductors. 2) Connecting temperature sensor wire Connect the temperature sensor wire to the two lower screws of the terminal block at the back of the thermostat (no polarity need to be respected). The wire must pass outside the electrical box and follow the wall down to the floor. The sensing probe should be placed in a representative heat area for maximum system perfomance. The sensing probe should be centered between the wires in the mat. The temperature sensor wire cannot cross any heater wires and the sensing probe must not be directly or adjacent to a heating wire. 120 VAC 60 HZ 120 VAC 60 HZ 920-111-021-00-1-A 1/2 OPERATING MODES The TH111GFCI-P has two (2) operating modes. MANUAL( ) This mode allows you to maintain a constant temperature of the floor. 1- To activate this mode, press on Mode button to display the icon. 2- Set the desired temperature using the buttons or select the pre-programmed or or settings. (To select the setting, press on a...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories