Facilité d'utilisation
In the screen, n/a indicates that the remote sensor is not attached. To change the temperature calibration, press Up or Down to select the internal or remote sensor. Once selected, press Plus (+) or Minus (-) to change the temperature calibration to the desired setting. Press Refresh (right blank button) to update the information on this screen. Note: When you change a temperature calibration and exit this screen, it may take a few seconds for the new temperature to be displayed on the Thermostat control screen on page 4. Figure 10. Sensor calibration screen Up Down Done Plus Minus Refresh Screen navigation buttons include: Done. Return to the Main menu screen on page 7. Plus. Increase the temperature by one degree. Minus. Decrease the temperature by one degree. Refresh. Blank button. Refresh screen temperatures. Up. Move selection pointer up. Down. Move selection pointer down. Sensor Calibration Done + - Internal (75) 1 Remote 1 n/a 0 Remote 2 n/a 0 Remote 3 n/a 0 Backlight display screen The Backlight display screen (Figure 11) is a sub screen of the User settings screen. The Backlight display screen allows you to set the backlight on and off brightness levels and contrast. Figure 11. Backlight display screen Backlite/Display Done + -Select Backlite Timeout 0 ON Level 100% OFF Level 0% Contrast 5 Done Plus Minus Select Up Down Screen options include: Backlight timeout. Set the time after the last button press that the backlight will timeout and turn off. You can adjust the time to 0 or from 20 to 40 seconds. If set to 0, the backlight will never timeout and will always be on. If set in the 20 to 40 second range, the backlight will turn off after the selected time expires. On level. Set the brightness of the backlight when it is on. You can adjust this setting in 10% steps, 0 to 100%. If set to 0, the backlight will never be on. Typically this setting is set to 100%. Off level. Set the brightness of the backlight when off. You can adjust this setting in 10% steps, 0 to 100%. If you do not want the backlight to go completely dark when off, you can set an off brightness to something greater than 0%. When you select an on or off brightness, the display changes to that level for you to observe the brightness setting. Contrast. Set the contrast level of the LCD display. You can adjust this setting from 0 to 10. Use this control to adjust the darkness of the display. Too light and the display looks faded, too dark and dark lines will appear in the display. Typically 5 is the correct setting. Screen navigation buttons include: Done. Return to the User settings screen on page 12. Plus. Increase the selected value. Minus. Decrease the selected value. Select. Select the function to be set. Up. Move selection pointer up. Down. Move selection pointer down. SmartCommand Thermostat Installation Manual Thermostat information screen The Thermostat information screen (Figure 12) displays the current configuration of the thermostat wall display unit and the HVAC control unit. This information is useful for quick check of firmware versions and HVAC system setup. It also shows the network address setting Thermostat information displayed includes: Wall display unit. Model and firmware version number. Control unit. Model and firmware version number. System type setting. Standard or Heat Pump (HP) HVAC system. Fan type setting (for standard systems). No fan with heat (gas systems) or fan with heat (electric systems). Changeover setting (for heat pump systems). Changeover with cool or changeover with heat. Note: You will see a Fan type setting for standard systems or a Changeover setting for HP systems. Network address setting. RS485 network address, 1 to 254 (default 1). Figure 12. Thermostat information screen Thermostat Info Done TS40R Ver: 3.07.6P HFRP Ver: 03.05.2 System Type: Standard Fan Type: No Fan w/HT Network Address: 1 Done Thermostat information screen has one navigation button, the Done button. Press Done to return to User settings screen on page 12. Installer settings screen The Installer settings screen is a hidden screen designed for installer use only. Do not change any settings in this screen unless you are a qualified service technician. Changing these settings will affect the operation of the heating/cooling system. To enter this screen, go to the Main menu screen on page 7 and press and hold the two inner control buttons for three seconds until the Installer settings screen (Figure 13) appears. The Installer settings screen displays the current internal settings of the thermostat. You can view and change the settings from this screen. Scroll to the desired function and press Plus (+) or Minus (-) to change the value. Figure 13. Installer settings screen Installer Settings Done + -Select Display Lock N Service Mode Network Settings MaxHeat SP 109 Up Down Done Plus Minus Select Screen navigation buttons include: Done. Return to the Main menu screen on page 7. Plus. Increase value by 1 or change from N to Y. Mi...
Ce manuel est également adapté pour les modèles :Thermostats - CC-SCSTAT (243.03 kb)