Log:
Évaluations - 3, GPA: 3 ( )

Instructions Carrier, Modèle 48/50TF

Fabricant : Carrier
Taille : 272.76 kb
Nom Fichier : 48_50h,t-15si.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Only one sensor can be wired. LEGEND C— Contactor IAQ — Indoor Air Quality CHAS — Ground NC — Normally Closed COM — Common NO — Normally Open DX — Direct Expansion OAT — Outdoor-Air Thermostat ECON — Economizer SAT — Saturated-Air Temperature GND — Ground Factory Wiring HT — Heat Field Wiring Fig. 9 — Apollo Control Wiring Schematic — 50HJQ, 121/2 and 15 Ton Units 7 GROUNDTRAN24 VAC20 VA(FIELDSUPPLIED)24 V H G 24 VACOR + - 24 VDC 2 1 8 7 6 5 4 3 2 1 ++- 2-10VDCSIG COM (J5-3)4-20mA (J5-2) NCCOMNO ALARMRELAYCONTACTS TANVIOWHTRED OAT VIOPNK DAT ECACCESSORYONLY OATCOMOAH+15VRATCOMRAH+15VCO2+CO2 COMDATCOMREM POTCOMLEDCOM CONTROLLERB1Y1Y2GCOMAO24 VAC24 COMGNDCLG1CLG2ECONOMI$ER OPTION/ACCESSORYREDBLUPNKBRNGRN DM YELWHTBLK FANHEAT 2HEAT 1 NCHEAT 1HEAT/FAN COMCOOL 2COOL 1COOL COMRCGROUND24 VAC/10 VA AUXILIARYRELAY** TO CARRIERHVAC UNITFIELD SUPPLIEDWIRING 13121110987654321 1 2 3 4 FAN RVSINGLE ZONERELAY PACKWITH AUXILARYRELAY COOL HEAT 1234567891011121314151617 SINGLE ZONE RELAY PACK CIRCUIT BOARD OAT SAT DXFAN STATUS IAQ STATUS†WHTREDBLUYELGRN WHTREDGRNBLKGRNBLK FILTERSTATUS HUMIDITYSENSOR TSP01TERMINALNUMBER#1#2#10#11#10#11 ADDITIONAL SENSORS* BLKRED REMOTE ROOMTEMP. SENSOR NETWORK BLKREDGRNINDOOR AIR QUALITY (CO ) SENSOR(33ZCSENCO2) TYPICAL WIRING DIAGRAM 2 JUMPERS LEGEND CO2 — Carbon DioxideCOM — CommonDAT — Discharge Air ThermistorDM — Damper MotorDX — Direct Expansion Coil SensorEC — Enthalpy ControlHVAC — Heating, Ventilation, and Air ConditioningIAQ — Indoor-Air QualityNC — Normally ClosedOAT — Outdoor-Air ThermostatRV — Reversing ValveSAT — Supply- Air Temperature SensorTEMP — TemperatureTRAN — Transformer (Field Supplied) VTS — Carrier TEMP SystemVVT® — Variable Volume/Variable TemperatureField-Supplied Wiring GROUNDTRAN24 VAC20 VA(FIELDSUPPLIED)24 V H G 24 VACOR + - 24 VDC 2 1 8 7 6 5 4 3 2 1 ++- 2-10VDCSIG COM (J5-3)4-20mA (J5-2) NCCOMNO ALARMRELAYCONTACTS TANVIOWHTRED OAT VIOPNK DAT ECACCESSORYONLY OATCOMOAH+15VRATCOMRAH+15VCO2+CO2 COMDATCOMREM POTCOMLEDCOM CONTROLLERB1Y1Y2GCOMAO24 VAC24 COMGNDCLG1CLG2ECONOMI$ER OPTION/ACCESSORYREDBLUPNKBRNGRN DM YELWHTBLK FANHEAT 2HEAT 1 NCHEAT 1HEAT/FAN COMCOOL 2COOL 1COOL COMRCGROUND24 VAC/10 VA AUXILIARYRELAY** TO CARRIERHVAC UNITFIELD SUPPLIEDWIRING 13121110987654321 1 2 3 4 FAN RVSINGLE ZONERELAY PACKWITH AUXILARYRELAY COOL HEAT 1234567891011121314151617 SINGLE ZONE RELAY PACK CIRCUIT BOARD OAT SAT DXFAN STATUS IAQ STATUS†WHTREDBLUYELGRN WHTREDGRNBLKGRNBLK FILTERSTATUS HUMIDITYSENSOR TSP01TERMINALNUMBER#1#2#10#11#10#11 ADDITIONAL SENSORS* BLKRED REMOTE ROOMTEMP. SENSOR NETWORK BLKREDGRNINDOOR AIR QUALITY (CO ) SENSOR(33ZCSENCO2) TYPICAL WIRING DIAGRAM 2 JUMPERS LEGEND CO2 — Carbon DioxideCOM — CommonDAT — Discharge Air ThermistorDM — Damper MotorDX — Direct Expansion Coil SensorEC — Enthalpy ControlHVAC — Heating, Ventilation, and Air ConditioningIAQ — Indoor-Air QualityNC — Normally ClosedOAT — Outdoor-Air ThermostatRV — Reversing ValveSAT — Supply- Air Temperature SensorTEMP — TemperatureTRAN — Transformer (Field Supplied) VTS — Carrier TEMP SystemVVT® — Variable Volume/Variable TemperatureField-Supplied Wiring *Filter status switch and humi...

Ce manuel est également adapté pour les modèles :
Thermostats - APOLLO CONTROL 48/50HJ004-024 (272.76 kb)
Thermostats - APOLLO CONTROL 50HJQ004-016 (272.76 kb)
Thermostats - APOLLO CONTROL 50TFQ004-012 (272.76 kb)
Thermostats - TM004-014 (272.76 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories