Log:
Évaluations - 3, GPA: 4.7 ( )

Instructions Honeywell, Modèle RC-90

Fabricant : Honeywell
Taille : 67.41 kb
Nom Fichier : 39fc7a8b-cc8b-4ed3-ba2d-83c8be3794c8.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


This thermostat has been tested and found to comply with the requirements of the European Union for Electromagnetic Interference, Electromagnetic Immunity and Safety under the applicable EMI and Low Voltage Directives and Standards. This thermostat has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. This product generates and can radiate radio frequency energy. Due to its low power design, it is unlikely to interfere with radio and TV communications. If it is suspected of doing so, the user is encouraged to try to correct the problem by reorienting the receiver's antenna, moving the receiver away from the product, or consulting an experienced radio/TV technician for help. As an EPA ENERGY STAR Partner, Home Automation, Inc. has determined that this thermostat meets the ENERGY STAR guidelines for energy efficiency. FCC INTRODUCTION Thank you for purchasing your new RC-90 electronic communicating thermostat. Your thermostat will provide you with comfort, convenience, and energy savings for years to come. We hope that you take a few moments to become familiar with all of the features of this fine product by reviewing this manual. Please keep this manual on file for future reference. DESCRIPTION The RC-90 is a precision digital thermostat for single stage heating and cooling systems. It has the capability of being controlled both locally and by remote control. It offers programmability, stand alone operation, and robust, optically isolated communications with automation systems, utility control systems, and personal computers. There are several items which can be configured at the time of installation. These items have a check box ( ) for your installer to indicate which features are used in your system. The RC-90 can act as the Master thermostat in a zoned heating and cooling system. Setting the Master thermostat to HEAT mode will allow it and the other zones to heat; setting the Master to COOL will allow it and the other zones to cool. Setting the Master to OFF will turn off all other zones. MAINTENANCE Your new thermostat is maintenance free. There is no battery to install or replace. If necessary, clean unit carefully with a mild soap solution on a soft cloth. 1 OPERATION To take advantage of all the benefits and features offered by your thermostat, we recommend that you start by becoming familiar with its operation. AUTO 4 ModeHold 2 Prog 3 Fan 5 1 DAY COOL : P 6 7 OMNISTAT 1- Display The Display is used to show current time, temperature, outdoor temperature (optional), mode, and to give useful information that will guide you through normal operation of your thermostat. 2- Hold Press the Hold key to set the system into Hold mode. In Hold mode, the thermostat will not change its settings by program. 3- Prog Press the Prog (programming) key to set the current time and day (hours, minutes, day of week), and to program the temperature time schedules for the MORN, DAY, EVE, and NITEperiods. 2 4- Mode Press the Mode key to set the thermostat mode to Off, Heat, Cool, or Auto. In Off mode, the heating and cooling systems are both off and do not respond to changes in temperature settings. In Heat mode, the heating system responds to maintain your desired heating setting. In Cool mode, the cooling system responds to maintain your desired cooling setting. In Auto mode, your thermostat will automatically switch between heat and cool to maintain your desired heating and cooling settings. 5- Fan Press the Fan key to set the system fan to Fan Auto or Fan On. In Fan Auto mode, the fan runs only when the system calls for heating or cooling. In Fan On mode, the fan runs continuously. 6- Down Arrow (U) Press the Down Arrow key to lower the desired temperature. 7- Up Arrow (U) Press the Up Arrow key to raise the desired temperature. Note: To check your desired setting without changing it, press the up or down arrow key (U or U) once. 3 DISPLAY The following icons will be displayed during normal operation: FAN AUTO 10 9 8 7 6 11 12 13 MORN DAY EVE NITE REMOTE HOLD HEAT OFF COOL 1 :: 2 OUTSIDE DESIRED A 4 5 3 1- Temperature Display Shows the current temperature, desired temperature, or heating and cooling settings. 2-Time Display Shows the current time of day. 3-DESIRED DESIRED is displayed when the temperature display shows the desired temperature setting. 4-OUTSIDE OUTSIDE will be displayed when the temperature display shows the outdoor temperature. The outdoor temperature will be displayed every 4 seconds. 4 5-. .. The . .. is displayed when the heating or cooling system is running. 6-COOL COOLis displayed when the system is in Cool mode. 7-AUTO AUTOis displayed when in automatic changeover mode. 8-HEAT HEATis displayed when the system is in Heat mode. 9-FAN FANis displayed when the fan is set to run continuously. 10-OFF OFFis displayed when the system is in the Off mode. 11-REMOTE REMOTE is displayed when the last command received by the thermostat was sent...

Ce manuel est également adapté pour les modèles :
Thermostats - RC-90 (67.41 kb)
Thermostats - RC-90 (67.41 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories