Log:
Évaluations - 7, GPA: 4.1 ( )

Instructions A&D, Modèle UA-704

Fabricant : A&D
Taille : 263.13 kb
Nom Fichier : 6dfa6c47-2d06-41e3-a972-a9fd460056cd.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Keys to Successful Monitoring: Blood pressure fluctuates throughout the day. We recommend that you are consistent in your daily measurement routine: • Measure at the same time every day. • Sit in the same chair/position. • Relax for 5 minutes before measurement. • Sit still during measurement – no talking, eating or sudden movements. • Record your measurement in a logbook. How Do I Record My Blood Pressure? Blood pressure readings are typically recorded with the systolic pressure written first, followed by a slash mark and the diastolic pressure. For example, 120 mmHg systolic and 80 mmHg diastolic measurements are written as 120/80. Pulse is simply written with the letter “P” followed by the pulse rate—P 72, for example. Please see Page E-13 for the blood pressure record. LifeSource Health Line (Toll-Free): 1-888-726-9966 E-12 . TM In Canada (Toll-Free): 1-800-463-5414 . E-13 TROUBLESHOOTING.SPECIFICATIONS .TROUBLESHOOTING.SPECIFICATIONS . Problem Probable cause Corrective action Display is blank, even when the Battery is drained. Replace with a new battery. power is turned on. Battery terminals are not in the correct position. Place the battery with negative and positive terminals matching those indicated in the battery compartment. The device will not measure. Readings are too high or too low. The cuff is not fastened properly. Fasten the cuff correctly. You moved your arm or body during the measurement. Make sure you remain very still and quiet during the measurement. The cuff position is not correct. Adjust the cuff position. Raise your hand so that the cuff is at the same level as your heart. You are wearing the wrong cuff size. See Pg. E-5 “Selecting the Correct Cuff.” Other The blood pressure reading is different from that measured at a clinic or doctor’s office. See Pg. E-12 “Keys to Successful Monitoring.” Remove the battery. Place back in correctly, and try the measurement again. Cuff will not inflate. Check air tube connection inside battery cover. NOTE: If the actions described above do not solve the problem, contact A&D Medical or Auto Control Medical at the numbers listed at the bottom of these pages. Do not attempt to repair the device yourself. . LifeSource Health Line (Toll-Free): 1-888-726-9966 E-14 Model . . . . . . . . . . . . . . . . . . .UA-704 Type . . . . . . . . . . . . . . . . . . . . .Oscillometric Display . . . . . . . . . . . . . . . . . .Digital, 10-mm character height Pressure/pulse displayed alternately Measurement range . . . . . . . . .Pressure: 20 mmHg to 280 mmHg Pulse: 40 pulses to 200 pulses/minute Accuracy . . . . . . . . . . . . . . . . .Pressure: +3 mmHg or 2%, whichever is greater Pulse: +5% Pressurization . . . . . . . . . . . .Manually by inflator bulb Depressurization . . . . . . . . . .Constant-air release-valve system Deflation . . . . . . . . . . . . . . . . .Hand-held push button Power source . . . . . . . . . . . . .1 AA battery (1.5 volt, included) Battery life . . . . . . . . . . . . . . .Approximately 2,000 measurements Operating environment . . . .50.F to 104.F (10.C to 40.C) Less than 85% relative humidity Storage environment . . . . . .-4.F to 140.F (-10.C to 60.C) Less than 95% relative humidity Dimensions . . . . . . . . . . . . . . .Length: 3.9”(100 mm) Width: 1.2”(31 mm) Height: 2.0” (51 mm) Weight . . . . . . . . . . . . . . . . . . .2.6 oz. (73 g) without battery Blood pressure measurements determined by the UA-704 are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method within the limits prescribed by the ANSI/AAMI SP-10 standard for electronic or automated sphygmomanometers. In Canada (Toll-Free): 1-800-463-5414 . E-15 CONTACT INFORMATION CONTACT INFORMATION Our products are designed and manufactured using the latest scientific and technological methods, and offer accurate, easy to use, home monitoring and treatment options. Our full product line includes: Aneroid Blood Pressure Kits Blood Pressure Cuffs Digital Blood Pressure Monitors Digital Thermometers Heart Rate Monitors Nebulizers Personal Health Scales Stethoscopes This LifeSource blood pressure product is covered by a Lifetime Warranty. See warranty card for details. Visit our web site at for warranty registration. For more information regarding use, care or servicing of your blood pressure monitor, contact: A&D Medical A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 LifeSource Health Line (Toll-Free): 1-888-726-9966 For Canada Residents, please contact: Auto Control Medical 6695 Millcreek Drive, Unit 5 Mississauga, Ontario L5N 5R8 Canada Auto Control (Toll-Free): 1-800-463-5414 E-16 . IMPORTANT! If You Need Assistance with the Set-Up or Operation We Can Help! Please call us FIRST before contacting your retailer at LifeSource Health Line 1-888-726-9966 - Toll Free 1-800-463-5414 - In Canada A specially trained representative will assist you A d...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories