|
Facilité d'utilisation
For department 41-99: To program zero dsDept. code Unit price (max. six digits) A To program another department, start from the beginning without pressing the Akey. Key operation example Print 1000 . A Unit price If a department is not programmed to allow the entry of preset unit prices in functional programming, the department is automatically changed to allow the entry of preset unit prices by this programming entry. 2 PLU/UPC Programming The cash register can handle PLU codes and UPC codes. PLU (Price Look-Up) codes are used for PLU and sub-department functions: The PLU function allows speedy key entries whereby a price is automatically called up when a code is entered. The sub-department is a kind of “open PLU”, which requires you to enter a price after the PLU code is entered. PLU codes consist of 4-digit numbers and leading zeros can be applied to the PLU codes. The cash register allows you to keyboard UPC-A (number system character: 0,2,3,4,5), UPC-E, EAN-8 and EAN-13 barcodes. The register also allows you to keyboard add-on codes (2 digits or 5 digits) added to EAN-13 codes except ISBN and ISSN codes. Unit prices for UPC codes must be preset. This means that even if price information is contained in a code, the register does not refer to it for sales registration. A maximum of 7000 PLU or UPC codes settings are possible. Each one belongs to a department and acquires the department's parameters (dept. type (normal or bottle return), dept. group, tax status, SICS and sign). A commission group (0 to 2, 0: No commission is applied) can be assigned to each department for commission for clerks. Each commission amount for individual clerk is calculated based on the corresponding programmed commission rate and printed later on clerk reports. The cash register is preprogrammed so PLU1 through PLU1200 as PLUs (commission group: 0) associated with department 1 and preset unit price “0”. Unit price and associated department assignment *1 pTo program zero Unit price (max. six digits) PLU/UPC code AD*2 Associated Dept. key *1: To assign departments 21 through 40, press the department shift key. When the associated department is department 41-99: To program zero (1 to 99) *2: For a sub-department, set the limit amount of unit price entry. To program the following PLU/UPC, start from entering a unit price or an associated department code without pressing the Akey. To program another PLU/UPC, start from the beginning without pressing the Akey. Key operation example Print pdsAssociated dept. code AUnit price (max. six digits) *2 PLU/UPC code 1 p 125 . 323456789108 p 360 . A PLU code Unit price Associated dept. UPC code To delete a PLU/UPC code, use the following sequence: PLU/UPC code pvTo delete the following PLU/UPC To delete another PLU/UPC A Function selection pTo program “00” AsABPLU/UPC code * To program the following PLU/UPC To program another PLU/UPC *: Item: A B Commission group number PLU/sub-department selection (For PLU code only) Selection: Sub-department PLU* Entry: 0-2 (0: Non commission)(default:0) 0 1 When programming UPC codes, always enter 1 for B. Key operation example Print 1 p 10 sA PLU/sub-dept. selection Commission group number When you program all 7000 PLU/UPC codes, the programming sequence will be complete with a press of the skey. 3 Commission Rate Programming Based on each clerk’s sales total of each commission group and the corresponding commission rate, the commission amounts are calculated, which is printed on clerk reports. Commission rate s 28 @ @ Commission number (1 or 2) sA Commission rate (0.00 - 999.99) Key operation example Print s28 @ 1 @ 15 sA You must use a decimal point when setting a fractional rate. 4 Miscellaneous Key Programming The cash register provides miscellaneous keys such as %, &, -, f, q(when using as RA key), R (when using as PO key), K(when using as CONV key), t, C, X, Yand A(when using as CA key). While the cash register is pre-programmed so you can use these keys, you must set a currency conversion rate to use Kkey. You can also program these keys for more convenient use. Please refer to the data below for programming these keys. Factory setting is indicated with parentheses. %, & Percent rate (0.00%), tax status (non-taxable), sign (minus), item % and subtotal % entry* (both are allowed), percent rate limitation (100%) Amount (0.00), tax status (non-taxable), sign (minus), item and subtotal entry* - __ (both are allowed), entry digit limit (7 digits) Not necessary to program f q, R Entry digit limit (9 digits) Currency conversion rate (0.0000), currency conversion rate entry method - open or K preset (both are enabled) C, X, Yand A Compulsory entry of amount tender (not compulsory), entry digit limit (8 digits), footer printing (not printed) t(Manual tax) Entry digit limit (7 digits) * Item %/Item _ : Percent/discount calculation is applied to individual department and PLU/UPC. * Subtotal %/Subtotal _ : Percent/discount calculation is applied to subtotals. ...
Ce manuel est également adapté pour les modèles :Shop Equipment - TINSZ2602RCZZ (1.83 mb)