Corrects a condition where a network interface configuration could fail to complete with a
non-English CMC when configuring the interface through the TCP/IP tab with DHCP or a static
IP address

Resolves a situation where, under certain conditions, on reboots after an upgrade to 9.0, SAN/iQ
9.0 appears to detect and report an erroneous controller cache discard event long after the
original condition has been addressed, corrected and no longer exists
Patch set 03
Included in Patch Set 03 are the following fixes:

Address potential security issues in SAN/iQ 9.0

Prevent SAN/iQ process restart due to invalid SCSI command from any iSCSI initiator

Increase the efficiency of volume/snapshot re-synchronization calculations when a storage system
is restarted, or added to a cluster, or is replaced in a cluster

Update the location of a support log file so it gets rotated correctly and Log Utilization remains
in normal range

Added a critical alarm, "The ’Log Partition’ status is ’Read Only’" that is displayed when the
SAN/iQ log partition becomes read-only due to a previous hardware problem

The CMC, along with supporting patch 10054-04, now prevents an upgrade if the SAN/iQ log
partition is in an unexpected state

Added a Warning alarm “The SAN/iQ memory requirements check status is ’Insufficient’ Required
x GB” that is displayed when the storage server is offline because of insufficient memory

Allow upper case letters for IQN names

Suppress benign boot messages being displayed on the VGA console

CMC now correctly reports cluster usage when managing an 8.5 management group with a 9.0
CMC

CMC now connects to the management gateway/CIM server when accessing storage systems
via a separate management network

Edit Management Group now shows out-of-date Remote Copy relationships, so you can disassociate
them to clear an alarm about an old remote management group being down

Added new translated strings from the last patch set
Patch 10059: Enables cross-version Remote Copy where storage systems running SAN/iQ 8.0, 8.1,
and 8.5, that are not supported with SAN/iQ 9.0, get a SAN/iQ 9.0 manager, which allows them
to be configured as remote management groups and to receive remote snapshots from a primary
management group with storage systems running SAN/iQ 9.0.
Patch set 04
Included in Patch Set 04 are the following fixes:

Large multi-terabyte volumes with small or sparsely filled snapshots now no longer experience
degraded performance with Remote Copy

Large multi-site SAN clusters where Ethernet flow control is not configured now no longer experience
degraded performance with SAN/iQ 9.0

The Adaptive Load Balancing (ALB) bond configuration updelay parameter for both 1GbE and
10GbE has been changed to 30 seconds for more efficiency in failover situations

9.0 SNMP now reports accurate storage system performance statistics for storageRaidStats OIDs
in the Storage MIB

Allow special characters in SNMP community string, such as ~`!@$%^&*():;=+[]{}|,.<>?
6
Fixes


...

Ce manuel est également adapté pour les modèles :
données dispositifs de traitement - HP LeftHand 10.8 TB Virtual SAN SAS Base System (241.41 kb)
données dispositifs de traitement - HP LeftHand Integrated 2.0TB VSA VMware ESX 3 Bundle (241.41 kb)
données dispositifs de traitement - HP LeftHand Integrated 2.0TB VSA/VMware ESX 2 Bundle (241.41 kb)
données dispositifs de traitement - HP LeftHand P4300 2.4TB SAS Storage System (241.41 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories