Log:
Évaluations - 0, GPA: 0 ( )

Instructions HP, Modèle HP DL380 - WSS Clustered Gateway

Fabricant : HP
Taille : 111.15 kb
Nom Fichier :
Langue d'enseignement: ende
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


NOTE:
The upgrade log files—360_unistall.log and 361_install.log—can be viewed at
C:\Program Files\Hewlett-Packard\HP Clustered File System\conf\debug.
Upgrading subsequent nodes
After upgrading the node with the highest IP, upgrade the next highest IP node to HP Clustered Gateway
3.6.1 by following steps 1 – 5 above.
Post-upgrade steps
Performance dashboard
The HP Clustered File System 3.6.1 has an additional utility, Performance Dashboard, that gets installed
during the upgrade. Performance Dashboard provides performance information for the cluster, individual
servers, and PSFS filesystems. See the HP StorageWorks Clustered File System 3.6.1 administration guide
for details about how to use this performance monitoring utility.
Changes necessitated by the upgrade
After upgrading to HP Clustered File System 3.6.1, you may need to make the following changes
to your configuration:
• Upgrade filesystems for Alternate Data Streams (ADS)
• Upgrade filesystems for 8.3 support (only if 8.3 support is needed)
Upgrade filesystems for Alternate Data Streams (ADS)
HP Clustered File System 3.6.1 provides filesystem support for ADS. This support is enabled by default in
PSFS filesystems created on HP Clustered File System 3.6.1. PSFS filesystems created on HP Clustered
File System 3.6.0 or earlier releases must be upgraded to enable ADS support. When ADS support is
enabled on a filesystem, it cannot be later disabled.
The filesystem is upgraded with the psfscheck command, which enables this feature internally on the
filesystem. Consequently, a brief, cluster-wide outage of the filesystem is required during the upgrade.
(If 8.3 support is also needed, both features can be enabled at the same time as described in the
next section.)
To upgrade a PSFS filesystem for ADS support, take the following steps:
1. Stop all applications using the filesystem.
2. Run the following command at the Command Prompt (the command is shown on two lines
for readability):
%SystemDrive%\Program Files\MatrixServer\bin\psfscheck -e enableads

The device can be specified in several ways:
• By the drive let er, such as X:
• By the mount point (junction), such as C:\san\vol2
• By the psd or psv name, such as psd2p2 or psv3
3. Restart the applications that use the filesystem.
HP StorageWorks Clustered Gateway (server/software bundle) CGW361upgrade kit
5


...

Ce manuel est également adapté pour les modèles :
données dispositifs de traitement - HP DL380-SL Clustered Gateway (111.15 kb)
données dispositifs de traitement - HP ProLiant DL380G5-WSS Storage Server Clustered Gateway (111.15 kb)
données dispositifs de traitement - HP ProLiant DL380G5-WSS Storage Server Initial Cluster (111.15 kb)
données dispositifs de traitement - HP 3PAR StoreServ File Controller v2 Storage (111.15 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories