|
Facilité d'utilisation
In addition, if you do not follow the recommended care and maintenance instructions, micro-organisms may be able to grow in the water within the humidifier’s reservoir. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up. DAILY MAINTENANCE 1. Be sure the unit is OFF and is disconnected from the electrical outlet. 2. Remove the housing and the reservoir from the humidifier and place in sink or tub. 3. Carry the base of the unit to the sink, remove the wick frame and wicks, place in sink, drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean, and dry with a clean cloth or paper towel. NOTE: the base and wick frame are dishwasher safe TOP RACK ONLY. 4. Drain the water from the tank into the sink and rinse tank thoroughly. Wipe clean, and dry with a clean cloth or paper towel. 5. Put filters back in wick frame, replace on base, replace the housing, then refill tank with cool tap water as instructed earlier in the Filling Instructions. Do not overfill. 6. Follow Operating Instructions. WEEKLY MAINTENANCE Remove Scale: 1. Repeat steps 1-4 above. 2. Clean the base by partially filling the base with one 8-oz cup of undiluted white vinegar, or use Clean-Away™ by Bionaire®. Let solution stand 20 minutes, cleaning all interior surfaces with a soft brush. Dampen a cloth with undiluted white vinegar and wipe out entire base to remove scale. 3. Rinse with clean warm water to remove scale and the white vinegar solution before beginning to disinfect the reservoir. Troubleshooting for your Cool Mist Humidifier Trouble • LED not illuminated. • Mist output minimal to none. • Water leaks from water reservoir. • Water Filter turns brown. • Film on water reservoir. • Water cloudy. • Humidistat cycles on/off. • Very tight reservoir cap. Probable Cause . Unit not plugged in. . Power failure. . Filter has not absorbed water. . Mineral buildup in base. . Humidistat is set too low. . Wick Filter needs to be replaced. . Normal operation. . Rubber O-ring is missing or improperly placed. . Reservoir Cap not tight enough. . Your filter needs to be cleaned. . In areas with particular hard water your wick filter will need to be changed frequently. . Mineral deposits cause film on tank to build up. . Filter needs to be washed. . Using warm water to refill reservoir. . Humidifier is reacting to room humidity level. . Over tightened. Solution . Plug in unit. . Check circuit breaker or outlet. . Wait 15 minutes before starting humidifier. . Regular cleaning of tray after each use will help keep the unit functioning properly. . Set the humidistat to high. . Follow cleaning instructions in manual. . Mist is invisible. . Check to see if inlet or outlet grills are blocked. . Remove reservoir cap then replace or reposition ring. . Tighten the reservoir cap. . Follow cleaning instructions in manual. . Use Clean-Away™ Solution (DMS216), to order call 1-800-253-2764, or visit . Follow cleaning instructions in manual. . Refill using cool water. . Set the humidistat to a higher or lower setting. . Add liquid soap or petroleum jelly to cap gasket to ease opening. Frequently Asked Questions Question • What are the variables that affect run time? • How do I remove film on water tank? • How can I extend the run time? Answer The estimated run time for this humidifier is based on average room conditions. The actual run time of your humidifier is dependent on numerous variables such as: . Air exchange in the room where the humidifier is placed. . Room construction of the room where the humidifier is placed. . Temperature of the room where the humidifier is placed. . Humidity levels in the room where the humidifier is placed. . Movement of occupants and the opening and closing of doors in the room where the humidifier is placed. . Home furnishings in the room where the humidifier is placed. . See Daily Maintenance instructions. Regular cleaning is recommended. . Run your unit on the lowest setting. . If your unit has electronics, set it to your desired humidity level. The unit will turn on and off, which will extend the run time. . Fill the tank all the way full, place it on the base, let the water empty into the base until it stops bubbling, then refill the tank full again. This ensures maximum water capacity and will extend run time. TWO (2) YEARS LIMITED WARRANTY SAVE THIS WARRANTY INFORMATION A. This Warranty applies only to the original purchaser of this product. B. This Warranty applies ONLY to repair or replacement of any supplied or manufactured parts of this product that, upon inspection by JCS/THG, LLC authorized personnel, is shown to have failed in normal use due to defects in material or workmanship. JCS/THG, LLC will determine whether to repair or replace the unit. This Warranty does no...
Ce manuel est également adapté pour les modèles :Humidificateurs - BCM5555-CN (802.88 kb)