Log:
Évaluations - 2, GPA: 4 ( )

Instructions Essick Air, Modèle 726 series

Fabricant : Essick Air
Taille : 238.07 kb
Nom Fichier :
Langue d'enseignement: enesfr
Aller à la télécharger



Facilité d'utilisation


(The humidistat control knob is located on the right). The humidistat will turn the humidifier on when the relative humidity in your home is below the humidistat setting and will turn the humidifier off when the relative humidity reaches the humidistat setting. For initial operation, set the humidistat at its midpoint and adjust up or down from there to achieve the desired humidity level. Text Box: 700 Wick Placement Text Box: 700 Bottle Placement 4) Installez un nouveau filtre a meche avant le debut de la saison. 1) Nettoyez l’appareil tel qu’indique dans le chapitre portant sur les « Soins et l’entretien ». 2) Jetez les filtres a meche uses et toute eau dans le recipient. Laissez le boitier secher completement avant de le ranger. N’entreposez pas l’appareil avec de l’eau dans le recipient. 3) N’entreposez pas l’appareil dans un grenier ou dans un endroit ou la temperature est elevee. CARE AND MAINTENANCE Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal growth. Ordinary household bleach is a good disinfectant and can be used to wipe out the humidifier base and bottle/ reservoir after cleaning. We recommend cleaning your humidifier at least once a week to maintain optimum environmental conditions from your humidifier. We also recommend using Essick Air Bacteriostat Treatment each time you refill your humidifier to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle. Please call 1-800- 547- 3888 to order Bacteriostat Treatment reference part# 1970. REMOVING SCALE 1) Turn off unit and unplug from outlet. 2) Remove water bottle from the humidifier and place it with the cap up in a secure location. Locate the two internal spring latches on the front and rear of the base. Releasing these latches will allow removal of the top housing. Flex the rear latch and lift the back of the top housing off the base far enough to clear the latch. Flex the front latch and lift the complete top housing away from the base. Place the top housing on a flat surface. See illustration. 3) Place base of unit in dishwasher at this point or follow the directions for REMOVING SCALE and DISINFECTING UNIT. REMOVING SCALE 4) Carry base to sink. Lift the wick from the base allowing excess water to drain. 5) Rinse wick under freshwater only. Do not use soap, detergent, or any other cleaners on the wick. Leave in sink to drain. 6) Empty the water from the base and/or water bottle. Fill the base and/or water bottle with water and 8 oz. (1 cup) of undiluted vinegar. Let stand 20 minutes. Then empty solution. 7) Dampen a soft cloth with undiluted white vinegar and wipe out water bottle and/ or base to remove scale. Rinse the water bottle and/ or base thoroughly with fresh water to remove scale and cleaning solution before disinfecting. DISINFECTING UNIT 8) Fill the water bottle and/ or base with 1 gallon of water and add 1 teaspoon of bleach. Wet all surfaces on water bottle and/ or base only. Let solution stay for 2...

Ce manuel est également adapté pour les modèles :
Humidificateurs - 726 000 (238.07 kb)
Humidificateurs - 726 400 (238.07 kb)
Humidificateurs - 736 200 (238.07 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories