|
Facilité d'utilisation
Read instructions before operating. Retain for future reference. Instruction Leaflet INFO-LINE If after having read this leaflet, you have any questions or comments on your humidifier, call 1-800-253-2764 in North America. . IMPOR When using electrical appliances, basic safety pr should always be followed to r shock, and injury to persons, including the following: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. e could cause damage, particularly to wall paper water tank on the base. THE TANK WILL IMMEDIATELY EMPTY ABOUT A QUARTER OF THE WATER INTO THE BASE OF THE HUMIDIFIER (the humidifier tank and base hold about 1.4 gallons). NOTE: The BCM1745 produces a clean, cool, INVISIBLE moisture. It is normal not to see the moisture. To reach the maximum water capacity, remove and fill the tank a second time after it finishes emptying into the base. Replace the tank onto the base. A small amount of water may empty into the base. 4. Plug the power cord into the electrical outlet. OPERATING INSTRUCTIONS: 1. Move the Humidity Control Switch to the HI position. Move the Humidity Control to the LO setting to lower the humidification rate. Allow up to 30 minutes for the filter to fully absorb water and the unit to produce the maximum moisture output. NOTE: We recommend the use of the hygrometer which reads the actual humidity level in your room. A humidity level below 20% can be unhealthy'and uncomfortable. The recommended humidity level is between 40% to 50%. DO NOT DEFEAT THE SAFETY PURPOSE OF THIS POLARIZED PLUG IN ANY WAY. PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS CONSUMER SAFETY INFORMATION NOTE: This is an electrical appliance and requires attention when in use. NOTE: If moisture forms on the walls or windows of the room, turn off the humidifier. The room already has plenty of humidity and additional moisture may cause damage. NOTE: DO NOT block air inlet or outlet. CORD AND PLUG INSTALLATION SAFETY INSTRUCTIONS The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier. Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over. HOW COOL MIST WORKS Your Bionaire® Cool Mist humidifier draws dry air through the rear air intake grill area. This air is then passed through a moisture–laden wick filter, which retains the minerals and deposits in the water. The resulting moist air is directed back into the room from the top air grill. NOTE: This humidification system provides a cool, invisible moisture output. It is normal not to see the mist. NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The recommended humidity level is between 40%-50%. PRE-OPERATING INSTRUCTIONS: 1. Be sure the unit is disconnected from the electrical outlet and the power switch is in the OFF position. 2. Lift off the humidifier housing and the water tank (see Fig. 1). Check to see that the circular, extended life filter is installed correctly around the filter supports in the base (see Fig. 2). Replace the humidifier housing. 3. Twist off the tank cap by turning counter-clockwise and fill the water tank with cool, tap water. Replace the tank cap by firmly turning clockwise and then replace the Figure 1 A. Carry Handle B. Humidifier Tank C. Filter Check Indicator D. Humidifier Housing E. 3-Speed Humidity Control F. Humidifier Base A D B E F C Figure 2 A C B A. Circular Extended Life Filter B. Humidifier Base C. Circular Filter Supports 5. Replace the main housing and then the tank. 6. Repeat Operating Instruction steps. It will take about 30 minutes for the humidifier to reach maximum output. NOTE: You can purchase replacement filters (model BWF64) at a local retailer, by calling 1-800-253-2764, filling out the accessory card, or by visiting It is recommended that a replacement filter is purchased for uninterrupted use. CLEANING AND MAINTENANCE: Humidifiers provide comfort by adding moisture to dry, heated indoor air. To get the most benefit from the humidifier and avoid product misuse, follow all instructions carefully, specifically the operation, care and maintenance guidelines. Please note this is an electrical appliance and requires attention when in use. In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the humidifier's reservoir. Daily Maintenance: 1. Before cleaning, set control to the OFF position and unplug the unit from the electrical outlet. 2. Lift off the tank and the housing of the humidifier. 3. Carry the base and the tank to the sink, remove the wick filter, then drain and rinse the base and tank thoroughly to remove any sediment or dirt. Wi...
Ce manuel est également adapté pour les modèles :Humidificateurs - BCM1745C05EFM1 (134.52 kb)