SETTING THE ACCUSET, PROGRAMMABLE HUMIDISTAT: Follow the Pre-Operating instructions. The programmable humidistat is designed to operate between 30% and 65% relative humidity range. The recommended setting is between 40% and 50%. 1. To program a pre-set humidity level, press the MODE button until the AUTO speeds are displayed, beginning with AUTO HIGH. Choose your desired Auto speed setting. 2. Once you have chosen your Auto speed, choose your humidity setting by pressing the HUMIDITY SET button. The HUMIDITY SET button works in multiples of 5, beginning with lowest setting, 30% and ending with highest setting, 65%. STORAGE INSTRUCTIONS If your humidifier will not be in use for two days or more, or at the end of the season follow these instructions. 1. Clean and dry the humidifier thoroughly as per the Weekly Maintenance instructions above. 2. Let the humidifier dry completely before storing. Do not store with water inside the base. 3. Do not store with the reservoir cap in place. 4. Throw away the wicking filter. Do not store with wick filter in place. 5. Store in a cool dry location. CLEANING AND MAINTENANCE INSTRUCTIONS Humidifiers provide comfort by adding moisture to dry indoor air. To get the most of the benefit from the humidifier and avoid product failure, follow all maintenance instructions carefully. If the recommended care and maintenance guidelines are not followed, micro-organisms may be able to grow in the water within the humidifier. Daily Maintenance 1. Before cleaning, turn the power to OFF and unplug the unit from the electrical outlet. 2. Lift off the tank and the housing of the humidifier. 3. Carry the base and the tank to the sink, remove the wick filter, place in sink, then drain and rinse the base and tank thoroughly to remove any sediment and dirt. Wipe clean and dry with a clean soft cloth or paper towel (DO NOT use metal cleaning utensils or abrasive cleaners). 4. Put the filter back in the filter supports, relace the housing, then refill the tank with cool tap water as instructed in filling the water tank instructions. Weekly Maintenance Remove scale: 1. Repeat steps 1-3 above. 2. Clean the base by partially filling the base with one 8-oz cup of undiluted white vinegar, or by using Clean-Away® solution. Let solution stand 20 minutes, clean all interior surfaces with a soft brush. 3. Dampen a cloth with undiluted white vinegar and wipe out entire base to remove scale. 4. Rinse with clean warm water to remove scale and the white vinegar solution before beginning to disinfect the tank. Disinfect tank: 1. Fill tank with 1/2 teaspoon of chlorine bleach and 1/2 gallon of water. 2. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces. 3. Empty the tank after 20 minutes, and rinse well with water until the bleach smell is gone. Dry with a clean cloth or paper towel. 4. Refill the water tank with cool water; replace the housing and the water tank. Repeat ALL Operating Instructions. Troubleshooting for your Cool Mist Humidifier Trouble • Power light not illuminated. • Mist output minimal to none. • Water leaks from tank • Filter turns brown. • Film on tank. • Water cloudy. • Humidistat cycles on/off. • Very tight reservoir cap. Probable Cause . Unit not plugged in. . Power failure. . Filter has not absorbed water. . Mineral buildup in base. . Humidistat is set too low. . Wick Filter needs to be replaced. . Normal operation. . Rubber tank ring is missing or improperly placed. . Cap not tight enough. . Your filter needs to be changed. . Short filter life. . Mineral deposits cause film on tank to build up. . Mineral deposits cause film on tank to buildup. . Filter needs to be changed. . Using warm water to refill tank. . Humidifier is reacting to room humidity level. . Over tightened. Solution . Plug in unit. . Check circuit breaker or outlet. . Wait 15 minutes before starting humidifier. . Regular cleaning of tray after each use will help keep the unit functioning properly. . Set the humidistat to high. . Replace your wick filter (BWF65) by calling 1-800-788-5350 or visit . Mist is invisible. . Check to see if inlet or outlet grills are blocked . Remove tank cap then replace or reposition ring. . Tighten the cap. . Replace your wick filter (BWF65) by calling 1-800-788-5350 or visit . In areas with particular hard water your wick filter will need to be changed frequently. . Use Clean-Away Solution (DMS216), to order call 1-800-788-5350 or visit . Replace your wick filter (BWF65) by calling 1-800-788-5350 or visit . Refill using cool water. . Set the humidistat to a higher or lower setting. . Add liquid soap or pertroeum jelly to cap gasket to ease opening. SERVICE INSTRUCTIONS 1. Do NOT attempt to repair or adjust any mechanical functions on this unit. Doing so will void the warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified pers...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories