Length of cutout (16-1/2") is equal to the length of this sheet. TEMPLATE 13-1/8 16-1/2 STEP-BY-STEP INSTALLATION INSTRUCTIONSIMPORTANT: .................. Placement Information Mount the Model HUM-FP Fan-Powered Flow-Thru ....................................WARM AIR PLENUM ONLY. .................................................. shown in relation to the AC cooling coils. 7. Stand the evapo- rator pad upright with the black index mark on top. Make sure the wick is seated securely in the drip tray. 9. Reattach the cover assembly by hooking it at the top of the mounting frame. Secure the cover by turning the thumb screw at the bottom clock- wise . See Additional Instructions on Back ......Toll-free Contractor Helpline: 888-SKUTTLE (758-8853) Contractor E-line: techservice@skuttle.com IO-310 05/06 Goodman® is a registered trademark of Goodman Manufacturing Company, L. P. Amana® is a trademark of Maytag Corporation and is used under license to Goodman Company, L. P. All rights reserved. No. 000-0752-077 • Rev 5/05 HBP Installation Instructions and Mounting Template for Model HUM-FP ........................................................................................U WARNING: ......................................................................................................................................................................... ...................................................................................................................................................................................................................................... or void all warranties. ADDITIONAL WARNINGS: 1. Disconnect electrical power to the furnace before starting installation to avoid serious injury or electrocution. 2. Use care when cutting plenum openings and handling ductwork. Sharp edges may cause serious injury. 3. Do not cut or drill any air conditioning or electrical accessories during installation. Electrocution is possible if you come in contact with a live electrical wire. Blindnes can occur if refrigerant contacts your eyes. CAUTIONS: 1. Do not install the unit where freezing temperatures could occur, or where temperatures 5. Do not set humidity up to recommended levels if there is condensation on the inside could exceed 180.F. windows of any living space. Condensaion damage may result. 2. Do not install the unit on a furnace jacket. 6. Do not install the unit on any plenum where static pressure exceeds 0.4" W.C. 3. Do not install the unit on a plenum face where the blanked-off ends of the cooling coil 7. Do not install the unit where water pressure exceeds 125 psi. Leakage may result. ...................................................................................... .. ..........................................................................................................................................................................O 4. Do not set humidity higher than recommended. Condensation damages may result. codes, ordinances and regulations. 1. Tape the template (this entire sheet) onto the warm air furnace plenum, making sure it is level. 2. Trace around the template. (Cutout size is 13-1/8" wide by 16-1/2" long.) Remove the template. Accurately cut the plenum opening. 3. ................................................ control wires by grasping .................................................... and pulling straight out. 4. Remove the cover by turning the thumb screw (circled) counter clockwise Tilt and lift the cover off the frame. 5. Pull out the drip tray and evaporator pad assembly by grasping the top lip and tipping out. 10. Position the humidistat on either an interior wall of the home or the return air plenum of the furnace. In- stall by following the instruc- tions in the parts bag. 6. Place the mounting frame into the plenum opening so that the frame hooks over the bottom of the opening. Screw the frame to the plenum. 8. Place the drip tray on top of the pad. Reinstall the evaporator pad and drip tray. Model HUM-FP INSTALLATION INSTRUCTIONS (cont'd.) WARNINGS: Shut off power before wiring. DO NOT wire the Model HUM-FP ........................................................ UNLESS the board connections are 120 VAC. If, and only if, they are 120 VAC, install a receptacle and wire it to the board connections. Plug the ............................................................ DO NOT, under any circumstances, wire the yellow solenoid wires to the curcuit board, or any other power source! Wiring Diagram A 11a. Wiring Diagram A: Single-Speed Blower. For wiring with a 120 VAC single-speed blower, locate the blower motor junction box. Wire in a receptacle for the ...................................................................................................................... and furnace system operations. 12. Tap into the water supply line using the saddle valve provided. Follow the directions on the saddle valve bag. 13 14 13. Connect copper tubing from the s...