Log:
Évaluations - 5, GPA: 4.6 ( )

Instructions Garland, Modèle GIWOK 5.0 (SH/WO 5000)

Fabricant : Garland
Taille : 2.53 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


6. Save the limit of the (mains) power current with the key [ “ ]. On the console appears the message “please confirm”. Press the key [ “ ] again. The following message appears on the monitor: save linecurrent limit: ....... 7. Set the pan detector (see pan detector, Section 4): T increase pan detector (+) t decrease pan detector (-) The following message appears on the monitor: pan detector limit= ....... 8. Save the pan detector with the key [ = ].On the console appears the message “please confirm”. Press the key [ = ] again. The following message appears on the monitor: save pan detector limit: ....... 9. By input [ -? ] the mode of adjustment will be left. The following message appears on the monitor: see you again! 10 The mode for adjustment has a time-out function. After a 10 minute period, the mode of adjustment will automatically reset. The adjustments are now completed and it is not possible to make any other adjustments at this point. If further adjustments are necessary, you will be required to start from the beginning again! Technical information regarding the induction cooker is also available in real-time, in the clients mode. The following parameters listed below can be read: Output on the hyperterminal: 1: KK:68 CU1:22 CU2:22 B:33 --- --- F:20080 1: KK:68 CU1:22 CU2:24 B:33 --- --- F:20080 1: KK:67 CU1:22 CU2:24 B:33 --- --- F:20080 1: KK:67 CU1:22 CU2:24 B:33 --- --- F:20080 Meaning: 1:KK:68 CU1:22 CU2:22 B:33 --- --- F:20080CU Sensor 1 - InsideTemperature of the coilActive FieldHeat SinkTemperatureCU Sensor 2 - OutsideTemperature of the CoilError MessageStatus MessageFrequencyBoard The internal cooling fan will be activated once the heat sink temperature rises to 70°C (158°F). Parameters For (Mains) Power Current And Pan Detector Item Number (Article No.) Induction Cooker Model Mains-Power Current Pan Detector 99560101 BH/BA 1500, 120VAC, 1N, 1,5kW (GIU 1.5) 162 21 99560102 BH/BA 1800, 120VAC, 1N, 1,8kW (GIU 1.8) 187 21 99560103 BH/BA 2500, 208VAC, 1N, 2,5kW (GIU 2.5) 153 23 99560104 BH/BA 2500, 230VAC, 1N, 2,5kW (GIU 2.5) 140 27 99560105 BH/BA 2500, 240VAC, 1N, 2,5kW (GIU 2.5) 192 26 99560106 BH/BA 3000, 208VAC, 1N, 3kW (GIU 3.0) 180 26 99560107 BH/BA 3000, 230VAC, 1N, 3kW (GIU 3.0) 163 28 99560108 BH/BA 3000, 240VAC, 1N, 3kW (GIU 3.0) 99560109 BH/BA 3500, 208VAC, 1N, 3,5kW (GIU 3.5) 192 26 99560110 BH/BA 3500, 230VAC, 1N, 3,5kW (GIU 3.5) 187 28 99560111 BH/BA 3500, 240VAC, 1N, 3,5kW (GIU 3.5) 99560112 BH/BA 2300, 230VAC, 1N, 2,3kW (GIU 3.5) 99580001 BH/IN 2500, 208VAC, 1N, 2,5kW (GIU 2.5BI) 99580002 BH/IN 2500, 230VAC, 1N, 2,5kW (GIU 2.5BI) 99580003 BH/IN 2500, 240VAC, 1N, 2,5kW (GIU 2.5BI) 99560004 SH/BA 3500, 208VAC, 1N, 3,5kW (GIU 3.5) 192 36 99560005 SH/BA 3500, 230VAC, 1N, 3,5kW (GIU 3.5) 192 35 99560006 SH/BA 3500, 240VAC, 1N, 3,5kW (GIU 3.5) 185 23 99560007 SH/BA 5000, 208VAC, 3N, 5kW (GIU 5.0) 167 21 99560008 SH/BA 5000, 400VAC, 3N, 5kW (GIU 5.0) 99560009 SH/BA 5000, 440VAC, 3N, 5kW (GIU 5.0) 99580004 SH/IN 3500, 208VA...

Ce manuel est également adapté pour les modèles :
Hobs - GIWOK 3.5 (SH/WO 3500) (2.53 mb)
Hobs - GIU 1.5 (BH/BA 1500) (2.53 mb)
Hobs - GIU 1.8 (BH/BA 1800) (2.53 mb)
Hobs - GIU 2.5 (BH/BA 2500) (2.53 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories