Log:
Évaluations - 0, GPA: 0 ( )

Instructions Bosch, Modèle PBH615B80A/09

Fabricant : Bosch
Taille : 2.75 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


We recommend that the isolation valve be fitted prior to the cooktop to enable isolation of cooktop from gas supply. The valve must be easily accessible at all times. To find out the factory set gas type, see bottom of cooktop next to gas connection. Remove plastic cap from gas supply line prior to installation. Fit regulator (N.G.) or a test point (Universal LPG) directly to the R 1/2’’ connection. Direction of gas flow is indicated on the rear of the regulator. For position of the inlet connection refer Preparing to install: Use pipe compound or thread sealant, properly theaded pipes and careful assembly procedure so that there is no cross threading, etc., which might cause damage or leakage. Make sure that all connections peformed are free of leakage. The manufacturer does not accept any liability for leakage on connections performed by the installer or if the L-tube is moved or twisted. There are two ways to carry out the connection to the main gas line: ¦ The hotplate can be connected with rigid pipe as specified in AS/NZS 5601.1 ¦ Flexible Hose: If installing with a hose assembly, install with a hose assembly that complies with AS/NZS 1869 (AGA Approved), 10 mm ID, class B or D, no more than 1,2 m long and in accordance with AS/NZS 5601.1. Ensure that the hose does not contact the hot surfaces of the hotplate, oven, dishwasher or any other appliance that may be installed underneath or next to the hotplate. The hose should not be subjected to abrasion, kinking or permanent deformation and should be able to be inspected along its entire length with the cooktop in the installed position. Unions compatible with the hose fittings must be used and all connections tested for gas leaks. The supply connection point shall be accessible with the appliance installed. WARNING: Ensure that the hose assembly is restrained from accidental contact with the flue outlet of an underbench oven. Before Leaving-Check all connections for gas leaks with soap and water. DO NOT use a naked flame for detecting leaks. Ignite all burners both individually and concurrently to ensure correct operation of gas valves, burners and ignition. Turn gas taps to low flame position and observe stability of the flame for each burner individually and all together. Adhere the duplicate data plate to an accessible location near the hotplate. When satisfied with the hotplate, please instruct the user on the correct method of operation. In case the appliance fails to operate correctly after all checks have been carried out, refer to the authorised service provider in your area. It should be expressly noted that we cannot accept any liability for direct or indirect damage caused by wrong connection, leakage or improper installation. When being repaired, the appliance must always be disconnected from the mains supply; if required, notify our customer service. Converting the cooktop from Nat. Gas to Universal LPG To change injectors All work involved in installation, setting and adaptation to a different gas type must be carried out by authorised personnel from our Service Centre and must comply with current regulations and the conditions laid down by the local gas company. Request change-over injectors from our customer service deparment (refer injector chart below for sizes). Natural Gas Universal LPG Burner Hourly Gas Injector Hourly Gas Injector Consumption mark Consumption mark (MJ) (MJ) Auxiliary 3,60 90 3,50 50 Semi-rapid 6,50 118 6,00 67 Rapid 10,80 155 10,00 85 Wok 12,00 160 11,00 91 Before conversion the cooktop must be disconnected from the electricity and gas valves must be turned to the OFF position. Changing the nozzles of the burners on the cooktop 1. Remove the pan supports, burner covers and diffusers. 2. Change the nozzles using the spanner provided by our Service Centre (code 340847, for double and triple flame burners code 340808), taking special care to ensure that the nozzle does not fall when it is removed from the burner or when fitted. Ensure that it is completely tightened in order to guarantee the seal. Adjustment of the taps 1. Set the control knobs to minimum. 2. Remove the control knobs from the taps. It has a flexible rubber valve reinforcing ring. Press with the tip of the screwdriver to access the tap's adjusting screw. Never remove the valve reinforcing ring. The valve reinforcing rings guarantee the watertightness of the appliance's interior from liquids and dirt, which might otherwise prevent its correct operation. 3. Adjust the minimum ring setting by turning the by-pass screw using a flat head screwdriver. To adjust the minimum flame for N.G. replace the control knob onto the spindle, light the gas and turn the control knob to the small flame position. Screw the adjustment screw anti- clockwise to estabilish a minimum stable flame position. The flame should remain alight and not burn back to the injector when the valve is turned quickcly from ‘Full On’ to the “Minimum flame” position and back a few times. To adj...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories