The hose should not be subjected to abrasion, kinking or permanent deformation and should be able to be inspected along its entire length with the cooktop in the installed position. Unions compatible with the hose fittings must be used and all connections tested for gas leaks. The supply connection point shall be accessible with the appliance installed. WARNING: Ensure that the hose assembly is restrained from accidental contact with the flue outlet of an underbench oven. Before Leaving-Check all connections for gas leaks with soap and water. DO NOT use a naked flame for detecting leaks. Ignite all burners both individually and concurrently to ensure correct operation of gas valves, burners and ignition. Turn gas taps to low flame position and observe stability of the flame for each burner individually and all together. Adhere the duplicate data plate to an accessible location near the hotplate. When satisfied with the hotplate, please instruct the user on the correct method of operation. In case the appliance fails to operate correctly after all checks have been carried out, refer to the authorised service provider in your area. It should be expressly noted that we cannot accept any liability for direct or indirect damage caused by wrong connection, leakage or improper installation. When being repaired, the appliance must always be disconnected from the mains supply; if required, notify our customer service. Converting the cooktop from Nat. Gas to Universal LPG To change injectors All work involved in installation, setting and adaptation to a different gas type must be carried out by authorised personnel from our Service Centre and must comply with current regulations and the conditions laid down by the local gas company. Request change-over injectors from our customer service deparment (refer injector chart below for sizes). Natural Gas Universal LPG Burner Hourly Gas Injector Hourly Gas Injector Consumption mark Consumption mark (MJ) (MJ) (mm) Auxiliary 3,60 90 3,50 50 Semi-rapid 6,50 118 6,00 67 Rapid 10,80 155 10,00 85 Double 12,00 160 11,00 91 flame Triple flame 16,00 182 13,50 100 Before conversion the cooktop must be disconnected from the electricity and gas valves must be turned to the OFF position. -Remove the pan supports, burner covers and Changing the nozzles diffusers.Fig. 7. of the burners on the Fig. 7 cooktop Adjustment of the taps -Change the nozzles using the spanner provided by our Service Centre (code 340847, for double and triple flame burners code 340808), taking special care to ensure that the nozzle does not fall when it is removed from the burner or when fitted. Fig. 8. Ensure that it is completely tightened in order to guarantee the seal. Fig. 8 Set the control knobs to minimum. Remove the control knobs from the taps. Fig. 9. It has a flexible rubber valve reinforcing ring. Simply presson this seal with the tip of a screwdriver to allow accessto the tap adjusting screw. Fig. 9 Never remove the valve reinforcing ring. Adjust the minimum ring setting by turning the by-pass screw using a flat head screwdriver. To adjust the minimum flame for N.G. replace the control knob onto the spindle, light the gas and turn the control knob to the small flame position. Screw the adjustment screw anti-clockwise to estabilish a minimum stable flame position. The flame should remain alight and not burn back to the injector when the valve is turned quickcly from ‘Full On’ to the “Minimum flame” position and back a few times. To adjust the minimum flame position for ULPG the screw must be fully tightened down clockwise. If the by-pass screw cannot be accessed, disassemble the grease splash tray, which is fixed to the rest of the hob using a clip and screw mounting system. The following steps must be taken to remove the grease splash tray: -Remove all the burner covers, pan supports and control knobs. -Loosen the screws on the burners. Use the disassembly lever 483196 availablle from our Technical Assistance Service. To release the front clips, apply the lever to the area shown in figure 10. Fig. 10 To assemble the grease splash tray again, proceed in the reverse order to removal. It is important that all the seals are refitted to form a seal. These devices are essential for the correct operation of the appliance as they prevent liquids and dirt from entering the appliance. Refit the control knobs. Never remove the tap spindle. In the event of a malfunction, change the whole tap.Fig. 11. Fig. 11 Warning! After finishing, the sticker indicating the new type of gas must be placed close to the specifications plate. Operating instructions Burner locations 415 4 15 23 6 23 327 4 7 1 Pan supports 2 Control knobs 3 Auxiliary burner (up to 1 kW) 4 Semi-rapid burner (up to 1,75 kW) 5 Rapid burner (up to 3 kW) 6 Double-flame burner (up to 3,3 kW) 7 Triple-flame burner (up to 4 kW) There are indications to show which burner each control The gas burners knob operates. Fig. 12. Operation Fig. 12 5 It is essential t...
Ce manuel est également adapté pour les modèles :Hobs - PCH615B90A/01 (2.84 mb)
Hobs - PCH615B90A/07 (2.84 mb)
Hobs - PCQ715B90A/01 (2.84 mb)
Hobs - PCQ715B90A/07 (2.84 mb)