|
Facilité d'utilisation
5 6 Natural gas connection Pressure test point R 1/2 ” R 1/2 ” Pressure test point. GasketGasket Universal LPG connection Wok burner operation The wok control has 4 settings. Largest flame =The outer and inner burners are both operating on high flame. Large flame = The outer burner burns low and the inner burner burns high. Small flame = Only the inner burner burns high. Smallest flame = Only the inner burner burns low. For ongoing cooking a variable setting between the flame sizes can be used. Operating instructions Burner locations There are two ways to carry out the connection to the maingas line: 1 A. The hotplate can be connected with rigid pipe asspecified in AS5601 table 3.1. B. Flexible Hose: If installing with a hose assembly, install 2 with a hose assembly that complies with AS/NZS 1869 (AGA Approved), 10mm ID, class Bor D, no more than 1,2m longand in accordance with AS5601. Ensure that the hose does not contact the hot surfaces of the hotplate, oven, dishwasher or any other appliance that may be installed underneath or . Rapid burner . Medium burner . Control Knobs . Small burner . Big wok burner 4 56 2 3 11 6 7 4 5 1. Medium burner next to the hotplate. The hose should not be subjected to abrasion, kinking or permanent deformation and should be able to be inspected along its entire length with the cooktop in the installed position. Unions compatible with the hose fittingsmust be used and all connections tested for gas leaks. The supply connection point shall be accessible with the Depress control knob and turn anti-clockwise to “High Burner ignition & flame”position. Hold the knob down for a few seconds appliance installed. control until the flame ignites. Keep control knob depressed for a few seconds to activate the flame failure device. If ignition fails, depress knob again and wait for ignition. Turn anti-clockwise to set the flame to the desired intensity. If ignition fails depress knob and try again. If flame is not established in 15 seconds release the control knob and open a door and wait 1 minute beforeattempting a new ignition procedure. All burners are fitted with a flame failure device which shuts off the gas supply if the flame extinguishes for any reason. To re-ignite, wait 30 seconds for any unburnt gas to disperse before repeating the ignition procedure described above. To turn off the gas supply to a burner turn the control knob clockwise to the “OFF” position. (Refer Fig. 1 3 ) 13 Burner Position Graphic The control knob is used to adjust the flame of the gas burner. “Low flame” graphic= lowest output “High flame” graphic= higest output If the ignition sparkers are dirty, this makes the burners harder to light, so you should keep them as clean as possible. Clean them using a small brush andremember that the ignition sparkers must be treatedvery gently. WARNING: Ensure that the hose assembly is restrained from accidental contact with the flue outlet of an under- bench oven. Before Leaving- Check all connections for gas leaks with soapand water. DO NOT use a naked flame for detecting leaks. Ignite all burners both individually and concurrently toensure correct operation of gas valves, burners and ignition. Turn gas taps to low flame position and observe stability ofthe flame for each burner individually and all together. Adherethe duplicate data plate to an accessible location near thehotplate. When satisfied with the hotplate, please instruct the user on thecorrect method of operation. In case the appliance fails to operate correctly after all checks have been carried out, refer to the authorised service providerin your area. It should be expressly noted that we cannot accept anyliability for direct or indirect damage caused by wrongconnection, leakage or improper installation. When beingrepaired, the appliance must always be disconnected from the mains supply; if required, notify our customer service. Before conversion the cooktop must be disconnected from the electricity and gas valves must be turned to the OFF position. 1 Remove the trivets, burner caps and burner heads. 2 Change the injectors using a 7-mm socket wrench and be sure to tighten them down properly so that 3 Re-assemble the burner component parts in reverse order. To change injectors All work involved in installation, setting and adaptation to a different gas type must be carried out by authorised personnel from our Service Centre and must comply with current regulations and the conditions laid down by the local gas company. Request change-over injectors from our customer service deparment (refer injector chart below for sizes). Coverting the cooktop from Nat.Gas to NOTE: it is not necessary to adjust the primary air control on these burners. 6 7 mm Refer Fig. 7. they are fully airtight. Refer Fig. 8. 7 8 Universal LPG Natural Gas Hourly Gas Injector Injector Comsumption (MJ) Small Medium Large Hourly Gas Comsumption (MJ) 4,0 Big wok (Center Burner outer) Big wok (Center inner) Universal LPG 11,5 15 14,6 6,5 incl...
Ce manuel est également adapté pour les modèles :Hobs - PCN985FAU/08 (1.26 mb)
Hobs - PCR915B90A/01 (1.26 mb)
Hobs - PCT915B90A/01 (1.26 mb)