Log:
Évaluations - 2, GPA: 3 ( )

Instructions Delta Electronics, Modèle FHWC3055LSA

Fabricant : Delta Electronics
Taille : 1.59 mb
Nom Fichier : 316902442en.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Pay attention to the procedure described in the assembly instructions. Preparation • Determine the exact location of the range hood. • Plan the route for venting exhaust to the outdoors ). • Plan the power connection prior to installation so that electrical wiring will not be visible afterwards. • House wiring location: The junction box is located on the top right side of the hood. Wiring should enter the back wall at least 20” above the bottom of the installation height, and within 3-3/8” to 4-3/4” of the right side of the centerline / ). fig. 3-1/4” circle 6-1/4” dia. hole • Use the shortest and straightest duct route possible. • The wall breakthrough must be carried out by a professional prior to installing the range hood. Pay attention to the length of the exhaust hose when planning the wall breakthrough. The exhaust hose must reach the outer edge of the wall without any kinks. Important! If the exhaust hose leads through an outer wall, install a wall cap with damper or roof cap at the exterior opening (not delivered). This can be installed by the professional that performs the wall breakthrough. GB • If open are operated in the same room, ask your local chimney sweeper about the local regulations prior to installation. • If you are renting, then approval must be obtained from the owner of the property. • Attention! In order for the range hood to reach optimal performance, install it over the middle of the cooking area. • The following accessories are required to mount the range hood (not included): Exhaust duct Power drill with 3/16” and 1/8” bits Screwdriver Level Cable detector Measuring tape Duct tape fig. Center line 36” Installation height 8 to 9 ft Ducting installation guidelines • For safety reasons, ducting should vent directly outdoors (not into an attic, underneath the house, into the garage or into any enclosed space). • Keep duct runs as short and straight as possible. • Duct (elbows and transitions) reduce air • Back to back elbow and “S” turns give very poor delivery and are not recommended. • A short straight length of duct at the inlet of the remote blower gives the best delivery. • Transition to duct from the integral blower or remote duct transition as close to the downdraft as is possible. • Use a suitable 6” round duct. • Flexible metal round ducts should only be used when no other duct exists. Limit use to short lengths and do not crush when making corners. Installing the hood 7 Examples of possible ducting or air fig. recirculation fig. Roof pitch with Sidewall cap Recirculator flashing and cap Pipe Collar Pipe Collar Pipe Collar Installing range hood to the wall (Exhaust operation) IMPORTANT This range hood is very heavy. Adequate structure and support must be provided in all types of installations. Install framing for hood support • If drywall is present, mark the screw hole locations. • Cut away enough drywall to expose 2 vertical studs at the holes location indicated by the template. Install two horizontal supports ...

Ce manuel est également adapté pour les modèles :
Ventilateurs - FHWC3655LSA (1.59 mb)
Ventilateurs - FHWC3055LSA (1.59 mb)
Ventilateurs - FHWC3055LSA (1.59 mb)
Ventilateurs - FHWC3055LSA (1.59 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories