Instructions Zephyr, Modèle AK11005

Fabricant : Zephyr
Taille : 658.17 kb
Nom Fichier : breeze_manual.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


g. NEVER place a switch where it can be reached from a tub or shower. h. Make sure the power is off before installing, wiring or maintenancing. Important 3 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. NOT FOR USE OVER AN OUTDOOR GRILL. CAUTION To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. For indoor use only. Do not use over cooking equipment greater than 60,000 BTU/hr. This hood is not intended to be used as a shelf. OPERATION Always leave safety grilles and fi lters in place. Without these components, operating blowers could catch onto hair, fi ngers and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance. *NOTE: Please check for revisions before doing any custom work. ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customer’s responsibility: - To contact a qualifi ed electrical installer. - To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommended that a qualifi ed electrician determine that the ground path is adequate. Do not ground to a gas pipe. Check with a qualifi ed electrician if you are not sure the range hood is properly grounded. Do not have a fuse in the neutral or ground circuit. *National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575 This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product. A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and install appropriate connector if necessary. List of Materials 4 MODELS:BREEZE I - AK1124x, AK1100x, AK1136x BREEZE II - AK1200x, AK1236x PARTS SUPPLIED 1 - Hood 2 - Aluminum mesh fi lters 2 - Halogen light bulbs (GU-10, 35W) (pre-installed) 1 - 3-1/4” x 10” rectangular starting collar with damper (located inside hood body) 1 - Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED - Ducting, conduit and all installation tools - Cable connector (if required by local codes) - Recirculating Kit (0AK11-21001) M4 x 1” (4) M4 x 1-1/2” (4) M4 x 2” (4) M4 x 8 (10) Wood screw washers (4) Wire Caps (3) Light bulb removal Suction Cup (1) 5 Installation Ducting Duct pieces Total Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 Ft. x ( ) = Ft. 7”-10” Round, straight 1 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect.900 elbow 15 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect.450 elbow 9 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect.900 flat elbow 24 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. wall cap with damper 30 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect.to 6” round transition 5 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect.to 6” round transition 900 elbow 20 Ft. x ( ) = Ft. 6” Round, 900 elbow 15 Ft. x ( ) = Ft. 6” Round, 450 elbow 9 Ft. x ( ) = Ft. Ft. 6” Round, straight 1 Ft. x ( ) = Ft. Subtotal column 1 = Duct pieces Total Equivalent number length x used = 6” Round wall cap with damper 30 Ft. x ( ) = Ft. Round wall cap with damper 30 Ft. x ( ) = Ft. 7” - 10” Round, 900 elbow 15 Ft. x ( ) = Ft. 7” - 10” 7” - 10” Round, 450 elbow 9 Ft. x ( ) = Ft. Ft. Ft. Ft. 6” Round, roof cap 30 Ft. x ( ) = Ft. 7” - 10” Round, roof cap 30 Ft. x ( ) = Ft. Subtotal column 2 = Subtotal column 1 = Total ductwork = 6” round to 3-1/ 4” x 10” rect. transition 1 Ft. x ( ) = Ft. 6” round to 3-1/ 4” x 10” rect. transition 900 elbow 16 Ft. x ( ) = Ft. 7” round to 3 1/ 4” x 10” rect. transition 8 Ft. x ( ) = Ft. 7” round to 3-1/ 4” x 10” rect. transition 900 elbow 23 Ft. x ( ) = Ft. Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet. Installation – Mounting Height & Clearance 6 DUCTING A minimum 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow effi ciency. Always use rigid type metal ducts only. Flexible ducts could restrict air fl ow by up to 50%. Also use calculation (on page 5) to compute total available duct run when using elbows, transitions and caps. ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct ...

Ce manuel est également adapté pour les modèles :
Ventilateurs - AK11245 (658.17 kb)
Ventilateurs - AK11365 (658.17 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories