Fabricant : Wolf Appliance Company
Taille : 200.56 kb
Nom Fichier : 375f1ec2-96bd-7c54-d58f-ef53796e54bf.pdf
|
Facilité d'utilisation
Dimensions in parentheses are in millimeters unless otherwise specified. 2 Planning Information Planning Information Pro Island Ventilation Hood MODEL PI663418(R) BLOWER OPTIONS SPECIFICATIONS 1200 CFM Internal Blower as of Fall 2007 1100 CFM In-Line Blower 1200 CFM Remote Blower 804703 810317 808332 801642 Overall Width of Hood Overall Height of Hood Overall Depth of Hood (including rails) 66" (1372) 18" (457) 34" (864) 38" (965) 1500 CFM Remote Blower 804701 Internal Blower Option 1200 CFM Refer to Pro Ventilation Recommendations at the end of this section. In-Line Blower Option Remote Blower Options 1100 CFM 1200 or 1500 CFM ACCESSORIES Platinum decorative rails and stand-offs for both sides of the hood Discharge Duct Size Electrical Supply Requirements Vertical 10" (254) Round 110/120 V AC, 60 Hz 15 amp dedicated circuit 6" (152), 12" (305), 18" (457) and 24" (610) classic stainless steel duct covers Shipping Weight (shell only) 168 lbs (76 kg) Specifications are subject to change without notice. Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator sectionofourwebsite,wolfappliance.com. Dimensions in parentheses are in millimeters unless otherwise specified. 3 Planning Information Planning Information Pro Island Ventilation Hood MODEL PI663418(R) INSTALLATION SPECIFICATIONS LOCATION OF ELECTRICAL SUPPLY CENTERED THROUGH TOP OF HOOD 18" (457) HEIGHT OF HOOD 66" (1676) 34" (864) WIDTH OF HOOD DEPTH OF HOOD 30" TO 36" 30" TO 36" (762–914) (762–914) TO COUNTERTOP TO COUNTERTOP DIMENSIONS Overall Width of Hood 66" (1676) Overall Height of Hood 18" (457) Overall Depth of Hood (excluding rail) 34" (864) Countertop to Bottom of Hood 30" (762) to 36" (914) Location of Electrical Centered through top of hood See Installation Instructions shipped with unit for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. 4 Planning Information Planning Information Pro Island Ventilation Hood MODEL PI663418(R) INSTALLATION NOTES Refer to the illustrations and specifications for overall dimensions and installation specifics. Wolf Pro island ventilation hoods are recommended for use with any Wolf cooking appliance. The hood must overlap the cooking surface by a minimum of 3" (76) on either side. Installation of all Pro ventilation hoods should be 30" (762) to 36" (914) from the bottom of the hood to the countertop. Follow the dimensions shown in the Installation illustration on page 4. Wolf Pro island hoods are shipped without a blower assembly. Internal, in-line or remote blower assemblies are available. Blower options also vary with the volume of air that needs to be moved and the length of the duct run. Refer to the charts at the end of this section for Pro ventilation recommendations and blower options. IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower. Pro island hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Placement of the electrical supply is not critical, as long as you provide enough 120 V AC, 60 Hz power cable to make the electrical connection. Location of electrical is centered through the top of the hood as shown in the Installation illustration on page 4. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. Refer to the installation instructions shipped with each Wolf product for detailed specifications. This information can also be found on our website, wolfappliance.com. Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Planning Information Pro Island Ventilation Hood MODEL PI663418(R) DUCTING CONSIDERATIONS Wolf Pro island hoods are shipped without the blower assembly. Internal, in-line and remote blower assemblies are available. IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower. Pro island hoods have a vertical discharge location with 10" (254) round duct. A transition with backdraft damper is included. The hood will operate most efficiently when ductwork does not exceed 50' (15 m) in length. Local building codes may require the use of make-up air. Consult your local HVAC professional for specific requirements in your area. IMPORTANT NOTE: Wolf Pro island hoods must be vented to the outside. Use only metal ductwork. Refer to the illustration below for ducting considerations for Pro island hoods. Ducting for Pro island hoods. ROOF CAP OR REMOTE BLOWER 18" (457) HEIGHT OF HOOD ISLAND HOOD DUCTWORK INSTALLATION THROUGH ROOF 34" (864) DEPTH OF HOOD 10" ROUND DUCT VERTICAL DISCHARGE VERTICAL DISCHARGE ONLY FOR ISLAND HOODS. TRANSITION 141/8"W x 9"D TO 10" ROUND 7"H (INCLUDING FLANGES) SOFFIT, CABINET OR DUCT COVER 30" TO 36" (762–914) COUNTERTOP TO BOTTOM OF VENTILATION HOOD 36" (914) STANDARD FLOOR TO COUNTERTOP HEIGHT Dimensions in parentheses are in millimet...
Ce manuel est également adapté pour les modèles :Ventilateurs - PI663418 (200.56 kb)