Log:
Évaluations - 3, GPA: 4 ( )

Instructions Smeg, Modèle KCVR9NE

Fabricant : Smeg
Taille : 169.24 kb
Nom Fichier : KCVR9NE-GB.pdf
Langue d'enseignement: en
Photos et spécifications   Smeg  KCVR9NE
Aller à la télécharger



Facilité d'utilisation


KCVR9NE EN 2) Grease filter extraction: To remove the metal grease filter, follow the instructions carried in the General Instruction Booklet. KCVR9NE EN Electronic control system instructions for use: Technical Features: • Power supply from mains: 230 VAC – 50/60 Hz • Power consumption in standby: 20 mA • Max. load applicable to LIGHTS connection: 150 W • Max. load applicable to MOTOR connection: 400 W (capacitor motors only) • Microprocessor-controlled electronic control system. • Loads managed by solid-state components, opto-isolated from the mains. • Hardware and software EMC filtering. • Connection to electronic control board by flat cable (10 poles) protected by flexible sheath (outside diameter 8 mm). Low voltage circuits (5 V). • Possibility of operating an optional load at mains voltage. • Non-volatile internal memory (EEPROM) for storing system settings and flags. • Optional analog/digital input for sensor and/or external control. • Phase-cutting motor control. • SOFT-START light switch: turn the lights on gradually to guarantee better performance of electronic components. • Automatic sensing of mains frequency: number 50 flashing on display = 230 VAC – 50 Hz mains, number 60 flashing on display = 230 VAC – 60 Hz mains, • Software-enabled reception of remote control commands: all the hood's main functions can be controlled by an IR remote control protected by a propriety code, operating at 24+1 bit and with an IR carrier frequency of 36 KHz. • Software set-up procedure for selecting and permanently storing blower motor settings and enabling A.C. filter saturation alarm (for filter hoods). • FILTER saturation alarm and alarm reset control (hour TIMER for hood work). KCVR9NE EN Operating Features Keypad with 10 touch buttons + 2 digit display + IR-RX Buttons from left to right: • MOTOR ON/OFF Starts and stops the blower motor. The display shows the current speed setting. • SPEED – Reduces motor speed: V4 > V3 > V2 > V1 • SPEED + Increases motor speed: V1 > V2 > V3 > V4 • BOOST-SPEED MODE Enables BOOST-SPEED mode from any motor speed or when motor is off. To disable BOOST-SPEED, press the button again and stop the motor. BOOST-SPEED mode is set to operate for 10 minutes: during which the display alternatively shows HI and the remaining time and the dot at the bottom right flashes every second. After 10 minutes the system automatically reverts to the previous speed setting. • 24H AIR CHANGE Starts the blower motor at a speed that provides a flow rate of about 100 m3/h. When 24h AIR CHANGE is enabled the display shows 24. 24h AIR CHANGE cannot be enabled when either BOOST-SPEED or DELAY -OFF is enabled. • DELAY Enables and disables the hood’s complete shutdown (motor+lights) after 30 minutes: during which the display alternatively shows the motor speed and the minutes remaining and the dot at the bottom right flashes every second. To disable the DELAY press the button again or stop the motor. KCVR9NE EN • RESET FILTRI: Resets the filter saturation alarm if pressed for 2s when all the loads (motor+lights) are off. • If there is a metal Filter sat. alarm, FF appears on the display, after 100 h of operation. • If there is a CA filter alarm, EF appears on the display after 200h of operation. • REDUCE LIGHT INTENSITY • LIGHTS ON/OFF Turns the hood lights on and off at maximum intensity. The increase/reduce buttons adjust the lights’ intensity by 4 steps, excluding max. intensity. • INCREASE LIGHT INTENSITY Keypad lock: Locks keyboard functions (for example, when cleaning the glass surface) when all the loads are off and no alarm is on. To enable/disable this function, press the BOOST-SPEED button for about 5s until the two central segments of every digit on the display light up. KCVR9NE EN FILTER SATURATION ALARM; RESETTING THE HOOD WORKING HOURS COUNTER • After the hood has been running for 100 hours the display shows FF, meaning that the GREASE FILTERS should be cleaned; • After 200 hours of running, the display shows EF, meaning that the GREASE FILTERS should be cleaned and the A.C. filter cartridges replaced (the latter warning appears only if the A.C. FILTER alarm function has been enabled). NOTE: The warnings appear on the display only when the blower motor is off. Direct procedure for enabling/disabling remote control Turn off the motor and the lights and make sure that no alarms are on (filter saturation). Press and hold the DELAY button for about 5s, until: • “tc” flashes twice on the display, meaning that the remote control has been enabled; • “tc” flashes once on the display, meaning that the remote control has been disabled. SET-UP procedure The default configuration is as follows: • 400W motor powered by 230 VAC – 50/60 Hz; • A.C. FILTER saturation alarm disabled; • remote control disabled. ACCESSING THE SET-UP PROCEDURE: 1) To access the set-up procedure press button 24 for about 5s, until an animation appears on the display; when the animation starts you have about 5 seconds to perform the se...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories