Log:
Évaluations - 2, GPA: 4 ( )

Instructions Delta, Modèle VFB25ACH

Fabricant : Delta
Taille : 1.39 mb
Nom Fichier : 426253a3-8b0d-4e21-92e5-648766d709b0.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


2. Make sure that the electric service supply voltage is AC 110~220V, 50~60Hz. 3. Follow all local electrical and safety codes, as well as the Nation Electrical Code (NEC) and the Occupation Safety and Healthy Act (OSHA). 4. Always disconnect the power source before working on or near the ventilating fan, motor or junction box. 5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects. 6. Do not kink the power cord. 7. in Fig. A. 8. Provide suction parts with proper ventilation. 9. This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit. 10. These ventilating fans are intended for residential usage only. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. U se this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. 2. Before servicing or cleaning unit, switch power o at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. person(s) in accordance with all applicable codes and standards, 4. to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted ventilating fan must always be vented to the outdoors. 7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) – protected branch circuit. 8. These models are UL listed for tub and shower enclosures. 9. Do not use this unit with any other solid-state control device. Solid-state controls may cause harmonic distortion, which can cause motor humming noise. 10. panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 11. NEVER place a switch where it can be reached from a tub or shower. 12. Not to be installed in a ceiling thermally insulated to a value greater than R40 (This is required for installation in Canada only). CAUTION 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking area (Fig. B). 3. This product must be properly grounded. Turning angle too large Duct shrink Too many elbows Elbow near the body Body Fig. A Fig. B Fig. B Floor Cooling Area 1 Cool ing Equipment SUPPLIED ACCESSORIES Part Name Appeara...

Ce manuel est également adapté pour les modèles :
Ventilateurs - VFB25AC (1.39 mb)
Ventilateurs - VFB25AD (1.39 mb)
Ventilateurs - VFB25ADH (1.39 mb)
Ventilateurs - VFB25AEH (1.39 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories