Instructions Xpelair, Modèle DX100

Fabricant : Xpelair
Taille : 205.02 kb
Nom Fichier : DX100.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Description Xpelair fans have the following features: • Universal mounting kit allows window/ wall panel/ ventilation shaft/ ceiling mounting options. • Single speed extraction DX100 • Operate the fan using an on/off switch (not supplied). DX100PC • Operate the fan using integral pull cord. DX100T • Built-in timer automatically operates fan for a preset delay of up to 30 minutes. DX100H • Operates either when triggered automatically by the humidity sensor or when turned on at the on/off switch (light indicates when fan is operating in manual mode). DX100HP • Operates either when triggered automatically by the humidity sensor or when turned on using the integral pull cord switch (light indicates when fan is operating in manual mode). Built-in timer automatically operates fan for a preset delay of up to 20 minutes. DX100PIR • An integral body movement sensor operates the fan as long as movement is detected. Built-in timer automatically operates fan for a preset delay of up to 20 minutes. DX100VTD • Operate the fan using the on/off switch (not supplied). The fan will not start for approximately 2.5 minutes (+/- 27%). After this time, the fan will operate. When the fan is switched off, it will continue to operate for approximately 7.5 minutes (+/- 27%). • A double pole isolating switch with a minimum contact gap of 3mm (wall or ceiling mounted). • If metal switch boxes are used, earthing regulations must be followed. • Suitably rated 2-core cable (DX100, DX100PC, DX100HP and DX100PIR). • Suitably rated 3-core cable (DX100T, DX100H and DX100VTD). • 3mm electrician's screwdriver and no.1 or 2 Pozdriv screwdrivers. • A wall or ceiling on/off switch with built-in indicator light (DX100, DX100T, and DX100VTD). • To prevent a possible hazardous situation from water ingress, a condensation trap (Xpelair no. XCT100) must be fitted as close as possible to the fan in all situations where any section of the duct work is positioned higher than the fan itself. If wall mounting the fan, you will also need • Masonry drill, hammer & chisel (or core drill equipment if available). • Mortar to make good the hole if required. If window mounting the fan • You will need a window pane between 3mm and 6mm thick (preferably 4mm). • Do not install in glass 3mm thick if the window pane area is more than 0.2sq.m. • If installing in sealed double glazing, a specially manufactured unit should be obtained from the glazing manufacturer. You will also require a special kit, Xpelair Cat. ref. DXDG. • If installing in sash windows, you should mount the fan in the upper window. Secure the upper sash in the closed position and fit stops just below the level of the fan, to prevent damaging it when the sash is raised. • If installing in a panel which is between 9mm and 46mm thick, you will need a special kit, Xpelair Cat. ref. DXDG. Do not install these fans in a panel which is more than 46mm thick. If ceiling mounting the fan You will need to use the appropriate ancillaries for terminati...

Ce manuel est également adapté pour les modèles :
Ventilateurs - DX100 (205.02 kb)
Ventilateurs - DX100H (205.02 kb)
Ventilateurs - DX100PC (205.02 kb)
Ventilateurs - DX100PIR (205.02 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories