Log:
Évaluations - 4, GPA: 4.3 ( )

Instructions Greenheck Fan, Modèle KPEU722M

Fabricant : Greenheck Fan
Taille : 570.01 kb
Nom Fichier : c133f9fb-5db1-448a-be4e-6fc9c72f82f9.pdf
Langue d'enseignement: enfr
Aller à la télécharger



Facilité d'utilisation


left vent right vent Recommended standard fittings 90° elbow = 45° elbow = 5 ft. (1.5 m) 2.5 ft. (0.8 m) Installation steps 1. Put on gloves and safety glasses. Place cardboard or another form of protection on top of a flat surface where you can easily assemble the downdraft vent system. Remove parts packages, downdraft vent and blower box from carton. Remove all shipping materials, tape and protective film from downdraft vent and blower box. over counter support arm 2. Attach the left side and right side overcounter support brackets to the downdraft. Use 1 screw with each bracket. end cap 3. Attach the left side and rightside end caps to the downdraft. Use 1 screw with each end cap. support leg 4. Attach support legs to side of downdraft vent with two screws in each leg. Do not tighten screws. WARNING Excessive Weight Hazard Use two or more people to move and install downdraft vent. Failure to do so can result in back or other injury. 5. Carefully insert downdraft vent into countertop cutout. Two people are recommended to support the weight of the downdraft vent during lifting. Check that downdraft vent is parallel to side of cutout and that mounting brackets rest gently on countertop. level mark 6. Move support legs down against cabinet floor. Place a level against front of downdraft vent base and adjust position of legs until downdraft is level vertically. Use a pencil to mark the top of each leg on face of downdraft vent. Then mark location of support leg mounting holes on cabinet floor. Remove downdraft vent from cutout. Drill starter holes at each mounting screw location on cabinet floor. Align top of legs with pencil marks on face of downdraft vent. Tighten screws in legs. 7. Attach 10" (25.4 cm) round vent collar plate (supplied with exterior blower system) to front of downdraft vent using 4 hex washer nuts. 8. Remove the 2 Phillips-head screws attaching the wiring box cover and remove cover. Remove either the back or bottom knockout and install conduit connector. NOTE: Power supply cable needed between exterior blower assembly and blower box is not provided. 9. Determine the location where the exterior blower box will be located. Cut opening in roof or wall for vent system to exterior blower. Install exterior blower according to instructions supplied with the blower kit. Wall Installations: • Use caulking compound between mounting flange and wall. Roof Installations: • Follow standard roofing procedures. • The flashing sheet should be centered over the roof opening. • Lower edge of flashing should lie on top of shingles and upper edge underneath shingles. • Seal assembly between roof, fan and flashing with roofing mastic to prevent leaks. 10. Insert retractable downdraft vent into countertop cutout. Two people are recommended to support the weight of the downdraft vent during lifting. Position downdraft vent so it is centered in cutout and parallel to edge of cutout. Check that downdraft vent is vertical. Then attach lower support legs to cabinet floor with screws. When attaching undercounter bracket to underside of countertop, make sure that the screw length will not go through countertop when tightened. 11. Attach one undercounter mounting bracket on front upper right corner of downdraft vent with slot over vent mounting hole and flange against countertop. Attach other bracket to left side of downdraft vent. Carefully drill starter holes through undercounter mounting brackets into underside of countertop. Insert appropriate length screws into holes and tighten brackets to countertop. WARNING Electrical Shock Hazard Disconnect power before servicing. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock. 12. Disconnect power. vent box knockout wiring box cover green ground wire green conduit connector 13. Feed the power supply cable through the conduit connector and into wiring box. Connect the white wires together with a twist-on wire connector. Connect the black wires together with a twist-on wire connector. Attach the green (or green and yellow) ground wire to eyelet with green ground screw and tighten screw. Replace wiring box cover. ground screw green ground screw green ground wire exterior-mounted vent motor wiring 14. Remove vent box knockout and install conduit connector. Feed exterior-mounted vent motor wiring through conduit connector. IMPORTANT: Do not wire the exterior vent motor black and white wires into the wiring box. Wires must be connected as shown. Connect the white wires together with a twist-on wire connector. Connect the black wires together with a twist-on connector. Attach ground wire to eyelet with green ground screw and tighten screw. Tighten conduit connector clamp screws. 15. Reconnect power. microswitches behind filters ON/OFF button blower control knob filter or filters depending on model end cap 16. Push and hold for a few seconds the button on the top of the downdraft vent. Retractable section of downdraf...

Ce manuel est également adapté pour les modèles :
Ventilateurs - KPEU722M (570.01 kb)
Ventilateurs - KPEU722M (570.01 kb)
Ventilateurs - KPEU722M (570.01 kb)
Ventilateurs - KPEU722M (570.01 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories