WARNING: To reduce the risk of fire or electrical shock, do not use this fan with any solid-state speed control device. Do not install in a ceiling insulated to a value greater than R-40. IMPORTANT SAFETY INSTRUCTIONS Duct Collar Wiring Knockouts Housing Slots Scroll WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power off at Service Panel and lock Service Panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. INSTALLATION INSTRUCTIONS WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. B. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. D. Ducted fans must always be vented to the outdoors. E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application. F. NEVER place a switch where it can be reached from a tub or shower. G. For installation in sloped ceilings up to 12/12 pitch. H. Ductwork must point up. FOR BEST RESULTS When installing the Exhaust Fan/Light in a new construction site, install housing during the rough-in construction of the building. The blower unit, reflector and grille should be installed after the finished ceiling is in place. Refer to instructions on page 3 to install the Exhaust Fan/Light in an existing finished building. PLANNING DUCTWORK AND WIRING 1. Use 4" round duct. 2. Plan duct run from discharge opening of fan to the outside. For best fan performance, make duct run as short as possible and use minimum number of elbows. 3. Use optional NuTone ducting accessories as needed. Power/Blower Unit Tabs Night Light Socket (not provided on 8664RP) Reflector Assembly Wing Nut Mounting Springs (2) Grille/Lens Assembly FIGURE 1 IMPORTANT: Use wire suitable for 90°C. Plan to run 120vAC house wiring (with ground) from power source, through wall switches, to junction box in fan. For separate control of fan, light, and night light three wall switches are required. See NuTone Catalog for accessory switches. For separate control of fan, light, and night light, five conductors are needed between the wall switch box and the fan's junction box. (Night light not provided on 8664RP). INSTALLATION IN A NEW CONSTRUCTION SITE PREPARATION 1. Refer to Figure 1. Remove power unit/blower assembly from housing. A. Unplug power unit. B. Remove screw (located next to plug-in receptacle) which holds power/blower unit mounting plate in place. Save screw. C. Lift mounting plate at end near the plug-in receptacle until blower wheel clears the scroll. D. Remove plate by pulling its tabs out of slots in housing. Set power/blower unit aside until needed. 2. Remove one of the wiring knockouts from housing. MOUNTING THE HOUSING Note: When installing in existing construction, refer to page 3 Mounting Using Mounting Tabs Refer to Figure 2. 1. Locate fan housing next to ceiling joist. 2. Use wood screws (not provided) to loosely attach housing to ceiling joist through keyhole slots in mounting tabs. 3. Adjust housing so that it will be flush with finished ceiling. For the grille to fit properly, the housing's rim must not extend beyond finished ceiling surface. 4. When housing is properly adjusted, tighten screws in slots. Mounting Using Hanger Bars Refer to Figure 3. 1. Insert hanger bars in slots provded in housing. 2. Locate fan housing between joists so that the bottom of the housing is even with the planned finished ceiling. 3. Use screws or nails (not provided) to secure hanger bars to ceiling joists...

Ce manuel est également adapté pour les modèles :
Ventilateurs - 8673RP (798.22 kb)
Ventilateurs - 8664RP (798.22 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories