Log:
Évaluations - 3, GPA: 4 ( )

Instructions NuTone, Modèle NP64000

Fabricant : NuTone
Taille : 4.48 mb
Nom Fichier : V07451.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


PREPARE THE INSTALLATION Make sure that the following items are included: - Range hood - Accessories: • Filters • Bag of parts including: (4) lock nuts, (1) wire clamp, (8) 1/2” double thread screws, (2) wire connectors, (2) 1/2” standard screws, (6) 3/8 screws. Parts sold separately: - Interior blower Model P5 includes blower, rough-in kit, flow deviator and 31/4” x 10” adapter - Interior blower Model P8 includes blower, rough-in kit, flow deviator and 31/4” x 10” adapter and 31/4” x 14” adapter - In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition) - In-line and exterior blower rough-in plate model 332KR, required for all In-line or Exterior Blowers - Exterior blower assembly 331H, 332H, 335 or 336 - Halogen lights (120V, 50W, PAR 20) - Heat lamps (120V, IR 175W, PAR 38) - RMP Series Backsplash (optional) - Baffle filters (optional) - Transitions, duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options and model numbers. NOTE: For cabinets with recessed bottom, attach wood filler strips (not included) on each sides, as shown below. Use two (2) 2-inch wide strips for 30’’ wide hoods, and four (4) 2-inch wide strips for wider hoods, cut to length. See below for wood filler strip locations. HOOD LOCATIONS WIDTHS A B C 30’’ 2’’ N/A N/A 36’’ 2’’ 41/2’’ 41/2’’ 42’’ 2’’ 71/4’’ 81/4’’ 48’’ 4’’ 101/4’’ 111/4’’ HD0079AABC 3. INSTALL BACKSPLASH (OPTIONAL) Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of hood and range control panel or cooktop. (See instructions packed with backsplash.) 4. SELECT BLOWER OPTION (EXTERIOR OR INTERIOR) INTERIOR BLOWER: EXTERIOR BLOWER: Follow all subsequent steps of this manual. Refer to instructions packed with exterior blower and follow steps 6, 10, 12 and up of the present manual. - 6 5. CHOOSE THE OPENING (INTERIOR BLOWER) Remove the knockout for the chosen opening (horizontal at the back of the hood or vertical on rough-in plate). See pictures below. CAUTION When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove the knockout corresponding to the ducting installed (10’’ or 14’’). HD0076 HD0077 10’’ KNOCKOUT 14’’ KNOCKOUT 14’’KNOCKOUT 10’’KNOCKOUT Removing horizontal knockout opening on back of hood Removing vertical knockout opening on rough-in plate 6. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS) INTERIOR BLOWER: Secure the rough-in plate (provided with the P5 and P8 blower) inside the hood with four (4) lock nuts. See picture below. HD0042 EXTERIOR OR IN-LINE BLOWER: Purchase Model 332KR separately. Refer to instructions included with the rough-in kit. Secure the rough-in plate inside the hood with (4) lock nuts. 7. INSTALL THE DEVIATOR (INTERIOR BLOWER) YOU MUST install the deviator if you choose to vent the hood vertically. Install the deviator as shown. NOTE: If installed correctly, the deviator will protrude about 1/8” above the rough-in plate. HD0003 Inserting deviator into hood vertical opening - 7 8. INSTALL THE ADAPTER (INTERIOR BLOWER) Using two (2) standard 1/2’’ screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood using duct tape. HD0005 HD0006 9. INSTALL THE HOOD (ALL BLOWERS) INTERIOR BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread screws leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover, place the wire clamp, insert the cable in the hood and tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it in position. Make sure the adapter/damper assembly enters the ducting. Secure the hood by tightening the screws completely. HD0043 EXTERIOR OR IN-LINE BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread screws leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover on top of the hood and connect wiring (see instructions included with exterior or in-line blower). Place the hood under the cabinet and slide it in position. Secure the hood by tightening the screws completely. - 8 10. CONNECT WIRING (ALL BLOWERS) WARNING Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally. ! INTERIOR BLOWER: Connect cable into wiring box using wire connectors. Connect wires as follow: BLACK to BLACK, WHITE to WHITE and GREEN or BARE wire under ground screw. Reinstall wiring cover. DO N...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories