|
Facilité d'utilisation
D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA. 2 !! CAUTION 1. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 2. Take care when using cleaning agents or detergents. 3. Avoid using food products that produce flames under the Range Hood. 4. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 5. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 6. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced. 7. For best capture of cooking impurities, the bottom of the hood should be a minimum of 24" and a maximum of 30" above the cooking surface. 8. Two installers are recommended because of the large size and weight of this hood. 9. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel. 10. Please read specification label on product for further information and requirements. 3 PREPARE THE HOOD 8 -Mounting Screws Unpack hood and check contents. You should receive: 1 -Hood 1 -Decorative Flue Assembly 1 -Adapter 2 -Non-ducted recirculation filters 1 -Parts Bag (B080810471) containing: 1 -Mounting Bracket 1 -Discharge Collar 1 -Flue Mounting Bracket (4.8 x 38mm Pan Head) 4 -Mounting Screws (3.9 x 9.5mm Pan Head) 8 -Drywall Anchors 1 -Plenum 4 -Mounting Screws (3.4 x 15mm Flat Head) 2 - Mounting Screws (3.9 x 6mm Flat Head) 1 -Installation Instructions MOUNTING BRACKET DISCHARGE COLLAR FLUE MOUNTING BRACKET 8 MOUNTING SCREWS (4.8 x 38mm Pan Head) 8 DRYWALL ANCHORS 4 MOUNTING SCREWS (3.9 x 9.5mm Pan Head) DECORATIVE FLUE 4 MOUNTING SCREWS (3.4 x 15mm Flat Head) ADAPTER NON-DUCTED RECIRCULATION FILTERS PLENUM fig.1 2 MOUNTING SCREWS (3.9 x 6mm Flat Head) 4 INSTALL THE DUCTWORK (DUCTED HOODS ONLY) NOTE: To reduce the risk of fire, use only metal ductwork. 1. Decide where the ductwork will run between the hood and the outside. 2. A straight, short duct run will allow the hood to perform most efficiently. 3. Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs. 4. Install a roof or wall cap. Connect round metal ductwork to cap and work back towards hood location. Use duct tape to seal ROOF CAP ROUND DUCT DECORATIVE FLUE HOOD WALL CAP 24” TO 30” ABOVE COOKING SURFACE 6” ADAPTER the joints between ductwork sections. fig.2 WIRING Note: This range hood must be properly grounded. The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug 33-7/16" (85cm) max must be plugged into an outlet that is properly fig.3 installed and grounded. WARNING - Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance. Set the electrical power supply within the space covered by the decorative flues. Position the power socket at a maximum distance of 33-7/16” (850 mm) from where the lead exits from the hood (see illustration alongside). Make sure this does not interfere with the bracket fastening area or with the decorative pipe (where the flue touches the wall). Fit the plug into the power socket. 5 6 DISCHARGE COLLAR 6” DIAMETER DUCT DUCT CONNECTOR INSTALL FLUE MOUNTING BRACKET DUCTED AND NON-DUCTED 1. Assemble the flue mounting bracket, adjusting outside width as shown. Fig.5 2. Carefully center the mounting bracket directly over the range hood location. 3. Secure the bracket assembly to the ceiling using (2) 4.8x38mm mounting screws and drywall anchors. Make sure the bracket is pushed into the corner, tight against the wall and centered over the hood. FLUE MOUNTING BRACKET 7 - 3/4” (197mm) 3.9 x 6mm FLAT HEAD BRACKET SCREWS INSTALL MOUNTING BRACKET 1. Construct wood wall framing that is flush with interior surface of wall studs. Make sure: a) the framing is centered over installation location. b) the heigh...
Ce manuel est également adapté pour les modèles :Ventilateurs - NP50000 (1.26 mb)