Log:
Évaluations - 2, GPA: 3.5 ( )

Instructions Vermont Casting, Modèle 3930

Fabricant : Vermont Casting
Taille : 882.07 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


36 Care of Cast Iron ............................................................................................................................. 36 Cleaning the Glass .......................................................................................................................... 36 Glass Replacement ......................................................................................................................... 36 Gasket Replacement ....................................................................................................................... 37 Inspect the Vent System Annually .................................................................................................. 37 Check the Gas Flame Regularly ..................................................................................................... 37 Stove Disassembly .......................................................................................................................... 38 Wiring Diagrams .............................................................................................................................. 38 Replacement Parts ....................................................................................................................................... 39 Optional Accessories ................................................................................................................................... 42 Warranty ........................................................................................................................................................ 43 Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters Installation & Operating Instructions The Pinnacle (PDV20) and Stardance (SDVR) Direct Vent Room Heater, Model Nos. 3920, 3926, 3930, 3936, 3960, 3966, 3970, 3976, 4065, 4070, 4075, 4080, are vented gas appliance listed to ANSI Standard Z21.88b2002 and CSA-2.33b-2002 for Vented Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use at High Altitudes. The installation of the PDV20 and SDVR Direct Vent Room Heaters must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edition and CSA B-149.1 (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5” w.c. for Natural Gas and 10” w.c. for LP gas at maximum input.) Refer to Page 37 (RF only). This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. Installation and replacement of gas piping, gas utilization equipment or accessories, and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) installation or replacement of gas piping, or (b), the connection, installation, repair, or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has complied with all the requirements of the authority having jurisdiction. The PDV20 and SDVR Direct Vent Room Heaters should be inspected before use and at least annually by a qualified service agency. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean. The PDV20 and SDVR Direct Vent Room Heaters and the individual shut-off valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The PDV20 and SDVR Direct Vent Room Heaters must be isolated from the gas supply piping system by closing the individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. An accessible tap is located above the pilot/on-off knob for checking the inlet pressure. 'Direct Vent' describes a sealed combustion system in which incoming outside air for combustion and outgoing exhaust enter and exit through two separate concentric passages within the same sealed vent system. The system does not use room air to support combustion. The Direct Vent system permits the gas appliance to be vented directly to the outside atmosphere through the side of the house or vertically through the roof. This appliance is approved for bedroom installations in the U.S. and Canada. This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. The PDV20 and SDVR Direct Vent Room Heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Elec...

Ce manuel est également adapté pour les modèles :
Ventilateurs - 3926 (882.07 kb)
Ventilateurs - 3936 (882.07 kb)
Ventilateurs - 3960 (882.07 kb)
Ventilateurs - 3966 (882.07 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories