Facilité d'utilisation
Auto Path If the setting is below No room temperature on the transmitter, does the main valve and fan turn off? If the manual switch is set to REMOTE, press the mode button to display AUTO on the transmitter. Does the transmitter display the room and temperature setting? Yes Move switch from LOCAL to REMOTE. Press any key within 30 seconds. If the setting is above room temperature on No the transmitter, does the main valve and fan turn on? Yes Turn pilotstat knob to OFF to turn valve completely off 10004894 21 LHEDV Series Direct Vent Insert Comfort Valve system control sequence of operation with transmitter Light pilot burner Set manual switch to local or remote Release pilotstat knob Turn pilotstat knob from PILOT to ON Did the LED stop blinking? Yes No Five minute wait period Review LED failure analysis Cycle switch once and leave in remote. Press any key on transmitter for recognition operation Choose Local or Remote path. Set switch to manual or remote If manual switch is set to LOCAL, did main burner light? Transmitter con- trols fan Turn pilotstat knob to PILOT to turn off main burner Turn pilotstat knob to OFF to turn valve completely off Local Path Move switch from local to remote. Press any key on transmitter. Move switch back to localYes Yes No If the manual switch is set to REMOTE, press the mode but- ton to display "ON". Does transmitter con- trol the main burner and fan? Does transmitter change levels of flame height, fan speed and set temperature? Set levels of flame height and fan to “0” to shut off main burner and fan Turn pilotstat knob to OFF to turn valve completely off On Path Yes Yes Move switch from manual to remote. Press any key on transmitter. No LHEDV Series Direct Vent Insert Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the instructions in this manual. Always handle the logs with care as they are fragile and may also be hot if the fireplace has been in use. Fan Assembly The fan unit requires periodic cleaning. At least once per month in the operating season, open the lower louvre panels and wipe or vacuum the area around the fan to remove any build up of dust or lint. Cleaning the Standing Pilot Control System The burner and control system consists of: • main burner • pilot burner • gas orifice • thermopile • combination millivolt gas valve Most of these components may require only an occasional checkup and cleaning and some may require adjustment. If repair is necessary, it should be performed by a qualified technician. In order to properly clean the burner and pilot assembly, turn off the gas to the unit, remove the window frame panel and logs exposing the burner and pilot assembly. Clean all foreign materials from the top of the burner. Check to make sure that burner parts are clean. Visu ally inspect pilot. Brush or blow away any dust or lint accumulation. If pilot orifice is plugged, disassembly may be required to remove any foreign material from the orifice or tubing. To obtain proper operation, it is imperative that the pilot and burner's flame characteristics are steady, not lifting or floating. Typically, the top 1/8" of the thermopile should be engulfed in the pilot flame. (Page 12, Fig. 22) Trim Cleaning Clean the trim with a soft clean cloth, slightly dampened with lemon oil and buff with a soft dry cloth. Do not use brass polish or household cleaners as these products will damage the trim. Lemon oil can be obtained at supermarkets or hardware stores. 10004894 23 24 10004894 LHEDV Series Direct Vent Insert LHERDV20/LHECDV20 1a 1d 1b 1e LHERDV30/LHECDV30 1a 1d 1c 1e 1b 2 3 4 5 6a/b 7a/b 9 a/b 8a/b 14 19 16 18 10a/b 17 18 11a/b 12a/b 13a/b 15 20 .... .... .......... ...... .......... .... ...... 23 a/b 21 22a/b LOCAL REMOTE ON• PILOT •OFF LED 24a/b 25 26 27 28/29 30 31 32 33 35 34 36 41 40 42 43 44 45 46 48 47 49 50 4894 LHEDV parts 4/03 51 37 38 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. LHEDV Series 4894 LHEDV Series Direct Vent Insert LHEDV Series (continued) Ref. Description LHERDV20 LHECDV20 LHERDV30 LHECDV30 1. Log Set Complete 10005332 10005332 10004866 10004866 1a. Log Rear Left 10005333 (JR7) 10005333 (JR7) 10004874 (KR22) 10004874 (KR22) 1b. Log Rear Right 10005334 (JR8) 10005334 (JR8) 10004875 (KR23) 10004875 (KR23) 1c. Log Rear Center --10004876 (KR24) 10004876 (KR24) 1d. Log Front Left 10005335 (JR9) 10005335 (JR9) 10004878 (KR25) 10004878 (KR25) 1e. Log Front Right 10005336 (JR10) 10005336 (JR10) 10004879 (KR26) 10004879 (KR26) 2. Lava Rock Burner Package 57897 57897 57897 57897 3. Lava Rock Package --10001454 10001454 4. Burner Housing Assembly with Tiles 10005294 10005294 10004972 10004972 5. Ceramic Tile (Singl...
Ce manuel est également adapté pour les modèles :Ventilateurs - LHECDV30 (1.69 mb)
Ventilateurs - LHERDV20 (1.69 mb)
Ventilateurs - LHERDV30 (1.69 mb)