Instructions Hunter Fan, Modèle HR230

Fabricant : Hunter Fan
Taille : 202.92 kb
Nom Fichier : 91c4d8c6-4393-412d-95bd-2b9a968eeea4.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Generally, the dehumidistat(s) should be located in areas, such as a bathroom, that generate excess moisture. When a shower is used, the local humidity level will go above the dehumidistat setpoint and the ventilation system will switch to the high speed (maximum ventilation). The ventilation system will return to the previous setting when the humidity drops below the setpoint. NOTE: When there is more moisture in the outside air than the inside air (summer time), turn off the dehumidistat(s). Moisture laden outdoor air brought inside will not dry the house. If your heating system has a powered humidifier, make sure the dehumidistat is set at least ten percent relative humidity above your humidistat. It may be necessary to lower the humidistat setting to avoid condensation in the winter. 69-0854 6 Step 5 Step 5 Step 6 Your Fresh Air Ventilation System may utilize one or more wall switches to provide manual control of the system. If a high ventilation rate is desired, move a switch to the maximum position. The ventilator will run at high speed until the switch is returned to the normal position. NOTE: The ventilator will run at high speed if any device in the system (Perfect Climate Comfort Center, dehumidistat, timer or wall switch) is activated. 7 69-0854 GETTING THE MOST FROM YOUR FRESH AIR VENTILATION SYSTEM GETTING THE MOST FROM YOUR FRESH AIR VENTILATION SYSTEM Continual operation of the ventilation system is recommended for optimum reduction of indoor air pollution and control of humidity. Increased moisture removal will always occur at maximum ventilation rates. Use the Hi switch position when first occupying a newly built home to remove excess moisture from new wood, plaster, cement and other moisture absorbing construction materials. If your system is wired to a dehumidistat, it will switch the ventilator to the high speed setting whenever the humidity level goes above the setpoint. NOTE: When the amount of moisture in the outside air is greater than the amount in the inside air, running the ventilation system will not dry the home. This will occur most often in the summer months. Remote Override Switch Functions Your Fresh Air Ventilation System may incorporate one or more remotely mounted Perfect Climate Comfort Centers™, dehumidistats, timers or wall switches. When any of these devices are activated, the ventilator will run at the high speed. The ventilator will return to the previous setting when all the remote devices are deactivated. The remote override function, in combination with the Standby setting, is especially useful for intermittent bathroom exhaust where continuous ventilation is not required. Continuous operation is recommended except when the home is unoccupied, or when proper ventilation is provided by other means such as open doors and windows. Defrost Ventilators designed for use in cold climates are equipped with an automatic defrost system. The ventilator automatically detects restricted airflow in the heat transfer core when ice starts to form and a defrost cycle is initiated. The ventilator is closed off from the duct system, an auxiliary heater is turned on and the air inside the ventilator is recirculated continually to melt the ice that has formed. When the airflow returns to normal, the sequence is reversed and ventilation returns to normal. When the ventilator is in defrost, the LED indicator light on the control panel is illuminated. Defrost time is held to a minimum by Honeywell’s exclusive automatic defrost initiation circuit. 69-0854 8 MAINTENANCE INSTRUCTIONS FOR THE FRESH AIR VENTILATION SYSTEM MAINTENANCE INSTRUCTIONS FOR THE FRESH AIR VENTILATION SYSTEM CAUTION Electric shock hazard. Can cause personal injury or equipment damage. Before doing maintenance, disconnect power to the ventilator by unplugging the power cord. NOTE: Your Fresh Air Ventilation System must be maintained on a regular basis for the best efficiency. Honeywell recommends the Fresh Air Ventilation System be cleaned and checked at least twice a year, preferably at the start of each heating and cooling season. Check and/or Clean as Follows: HEAT TRANSFER CORE AND FILTERS The room air filter, fresh air filter and the heat transfer core are removed from the ventilator as a unit. 1. Remove the drain hose(s) from the bottom of the check valve. Turn the check valve and fitting out of the bottom of the ventilator. Use a wrench or pliers to loosen the fitting, if necessary. See Fig. 2. 9 69-0854 HOSE DRAIN HOSE FITTING CHECK VALVE CORE DRAIN HOLE DRAIN ACCESS HOLES ON BOTTOM OF HR230 M7610 Systemon a air frais HOSE DRAIN HOSE FITTING CHECK VALVE CORE DRAIN HOLE DRAIN ACCESS HOLES ON BOTTOM OF HR230 M7610 Systemon a air frais 69-0854 10 2. 2. DOOR TAB DOOR TAB SLOT DOOR LATCH DOOR LATCH BRACKET SLIDE DOOR LATCHES TO THE LEFT. WHEN DOOR IS RELEASED, PULL DOOR TABS OUT FROM SLOTS. 11 1 2 2 2 M7604 CORE ACCESS DOOR HR230 CABINET Fig. 3. Remove core access door. 11 69-0854 M7605 CORE FILTER CORE FILTER CORE...

Ce manuel est également adapté pour les modèles :
Ventilateurs - HR230 (202.92 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories