Log:
Évaluations - 3, GPA: 4.3 ( )

Instructions Air King, Modèle 4TM65A/9530A

Fabricant : Air King
Taille : 142.91 kb
Nom Fichier : air-king-9530.pdf
Langue d'enseignement: enes
Aller à la télécharger



Facilité d'utilisation


This work must be done only by a qualified electrician, using copper wire only. WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA. WARNING: THIS PLUG IS A SAFETY FEATURE. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, DO NOT REMOVE, REPLACE, REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG. IF THE FAN DOES NOT FUNCTION PROPERLY, IT MAY BE DUE TO THE SAFETY DEVICE INCORPORATED IN THIS PLUG. RETURN TO AN AUTHORIZED SERVICE CENTER OR CALL 800-233-0268, MONDAY - FRIDAY, BETWEEN 8:00 AM AND 5:00 PM EST. IF THE PLUG WARNING LABEL IS MISSING OR DAMAGED, CALL THE TOLL FREE NUMBER FOR A REPLACEMENT LABEL. 8. Where possible, avoid the use of extension cords. If they must be used, minimize the risk of overheating by ensuring that they are UL listed. Never use a single extension cord to operate more than one Fan. 9. Do not operate any Fan with a damaged cord or plug or after the Fan malfunctions, has been dropped or damaged in any manner. Return Fan to authorized service facility for examination, electrical or mechanical adjustment or repair. 10.Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire, or damage the Fan. Do not block or tamper with the Fan in any manner while it is in operation. 11.Always place the Fan on a stable, flat, level surface when operating, to avoid the chance of the Fan overturning. Locate the Power Cord so the Fan or other objects are not resting on it. Do not run Power Cord under carpeting. Do not cover Power Cord with throw rugs, runners, or the like. Arrange Power Cord away from room traffic and where it will not be tripped over. 12.This Fan is not intended for use in wet or damp locations. Never locate a Fan where it may fall into a bathtub or other water container. 13. Do not use Fan outdoors. WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES. SAVE THESE INSTRUCTIONS Rev. E 7/05 8 2084532 Rev. E 7/05 1 2084532 1 2011056 Switch Knob 1 2 2090008 Screw #8 x 1/2 Type 25 PPH 6 3 02030007AK Motor Assembly w/Cover and Cordset 1 4 2011051 Rear Grill 1 5 2011053 Blade 1 6 2091008 Lockwasher #12 External Tooth 1 7 2091160 Hex Nut 12-24 1 8 2011055 Ratchet Plate 2 9 2090017 Screws #8 x 1/2 Hex Sems 2 10 2011052 Base 1 11 2010415 Foot 4 12 2011054 Mounting Bracket 1 13 2011050P Front Grill 1 REPLACEMENT PARTS LIST Key Part No. Description Qty. Mark Center Figure 1 1/8" - 3/16" Stud Figure 2 2 4 3 5 6 7 8 10 11 12 2 13 11 8 9 1 MODEL 4TM65A/9530A SUPERIOR INFERIOR PLANTILLA NO SUMINISTRADOS - Dos (2) tornillos para madera no. 8 x 1-1/4” (Comprarlos por separado) . 4-1/8" (10.48 cm) OPERATION 1. Plug the Fan into any standard 120V AC household outlet. 2. Using the Rotary Switch, set the desired fan speed. 3. To rotate Fan, loosen Knobs on side of Grill and tilt to direct air flow. MAINTENANCE WARNING: ALWAYS UNPLUG THE CORD BEFORE SERVICING. CLEANING: Use a soft cloth and a mild soap solution such as liquid dish washing detergent. CAUTION: Do not use gasoline, benzine, thinner, harsh cleaners, etc. as they will damage the Fan. NEVER use ALCOHOL OR SOLVENTS. Dry all parts with a soft cloth completely before reconnecting to power supply. STORAGE: When not in use, keep unit in a clean dry place. MOTOR IS PERMANENTLY LUBRICATED. OPTIONAL: WALL-MOUNTING CONFIGURATION Two #8 x 1-1/4" Wood or equivalent Screws must be purchased separately for Wall-Mount configuration. 1. Remove Wall-Mount Template from this Instruction Sheet. 2. Place the Wall-Mount Template against the wall at desired height and mark the center of the two vertical holes. Make sure the chosen location is centered on a stud (unless wall anchors are being used). 3. Install a Screw (#8 x 1-1/4" Wood Screw or equivalent (2x)), NOT SUPPLIED - must be purchased separately), in each marked location. (Figure 1) 4. Tighten Screws down leaving a 1/8" to 3/16" gap between the wall and the bottom of the Screw Head. (Figure 2) IMPORTANT!!! MAKE SURE SCREWS ARE ENGAGING THE STUD. 5. Mount the Fan by aligning the two Holes on the Wall-Mount Bracket to the two Screws on the wall. Once the Fan is on, gently pull down making sure the Fan is securely fastened. * For proper brick wall installation use masonry anchors, not included, and follow instructions. This mounting procedure allows for the fan to be hung horizontally or vertically, a total of four positions, without relocating the screws. GARANTIA LIMITADA DE TRES ANOS DE AIRKING. AirKing garantiza el producto al usuarlo original, contra defectos de mano de obra o materiales en condiciones de uso normales. El motor esta garantizado por tres anos y todas las demas partes por un ano, a partir de Ia fecha de compra. Toda pieza qua AirKing determine que esta defectuosa en material o mano de obra y sea enviada a un centro d...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories