Log:
Évaluations - 4, GPA: 3.5 ( )

Instructions Carrier, Modèle HRVCCSVA

Fabricant : Carrier
Taille : 145.88 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


OPERATING YOUR HEAT RECOVERY VENTILATOR (HRV) WITH BASIC, STANDARD AND AUTOMATIC CONTROL Your HRV is designed to operate as an integral part of your total heating and cooling system. With the exception of high capacity models, which are available with standard controls only, all HRVs offer 4 control options (See Fig. 2). S Basic Controls: Allow the user to manually set the unit to low- -- or high- -- fan speed as required to maximize comfort. Controls may be unit mounted. S Standard Controls: Offer automatic dehumidistat control and the option to select low speed or intermittent fan during heating season. S Automatic Controls: In addition to the operational features found with standard controls, automatic controls feature a recirculation mode. Not for use with forced- -- air HVAC systems. Fan Speed Control—Enables user to modulate fan speed from low to high. Dehumidistat Control—Allows the user to select the relative humidity level at which the unit would change fan speed to avoid condensation problems while heating during the winter months. (See Table 1). Continuous Mode—If the relative humidity inside the building is lower than selected, air exchange would occur with the outside at low speed. If the relative humidity level inside the building is higher than selected, air exchange would occur outside at high speed. This ensures continuous air exchange for constant air quality. Intermittent Mode—If the relative humidity inside the building is lower than selected, no air exchange would occur, and the system would turn off. If the relative humidity inside the building is higher than selected, air exchange would occur with outside at high speed. This ensures minimum air exchange level when the building is unoccupied to minimize operating cost. Recirculation Mode—If the relative humidity inside the building is lower than selected, indoor air would be circulated and filtered at high speed. If the relative humidity inside the house is higher an selected, air exchange would occur with outside at high speed. This ensures continuous movement and filtration of air for maximum comfort. ! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before servicing system, always turn off main power to system. Turn off accessory heater power if applicable. There may be more than 1 disconnect switch. 2 CAUTION! CUT HAZARD Failure to follow this caution may result in personal injury. Although special care has been taken to minimize sharp edges in the construction of your unit, be extremely careful when handling parts or reaching into the unit. Wear appropriate protective clothing and gloves when working on this unit. PERFORMING ROUTINE MAINTENANCE 1. The motors are factory lubricated. Lubricating the bearings is not recommended. 2. The heat recovery core must be handled with care. To ensure maximum efficiency of the plastic partitions wash core once a year following the season of most intense use. Allow the heat reco...

Ce manuel est également adapté pour les modèles :
Ventilateurs - HRVCCLHA (145.88 kb)
Ventilateurs - HRVCCSHA (145.88 kb)
Ventilateurs - HRVCCSVU (145.88 kb)
Ventilateurs - HRVCCLVU (145.88 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories