Log:
Évaluations - 2, GPA: 4 ( )

Instructions Broan, Modèle U24211 EFT 630

Fabricant : Broan
Taille : 516.87 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


32 For the installer ....................................................................... 32 For the user ............................................................................. 32 Description of the Appliance ............................................... 33 Extractor version .................................................................... 33 Recirculation Version ............................................................. 33 Control Panel ........................................................................ 34 Correct ventilation .................................................................. 34 Maintenance and Care ......................................................... 35 Cleaning the hood ................................................................... 35 Metal grease filter ................................................................... 35 Paper grease filter ................................................................... 36 Charcoal filter ......................................................................... 36 Changing the light bulb .......................................................... 36 Something Not Working ...................................................... 37 Special accessories ................................................................ 37 Service and Spare Parts ....................................................... 38 Guarantee Conditions .......................................................... 39 Technical Specifications ....................................................... 40 Installation ............................................................................ 40 Unpacking ............................................................................... 40 Fitting ..................................................................................... 40 Electrical connection .............................................................. 40 Mounting accessories included .............................................. 41 Wall unit mounting ................................................................. 41 Wall mounting ........................................................................ 41 Before installing or using this appliance please read this instruction book carefully paying particular attention to the safety warnings on the following page. If you have any queries regarding this appliance please contact Customer Care for advice. Please keep this instruction book for future reference and pass it on to any future owner of the appliance. 31 Safety warnings For the installer • When used as an extractor unit, the hood must be fitted with a 125mm diameter hose. Attention: The hose is not supplied and must be purchased separately. • When installing the hood, make sure you respect the following minimum distance from the top edge of the cooking hob/ring surfaces: electric cookers 600 mm gas cookers 650 mm coal and oil cookers 800 mm min. • The national Standard on fuel-burning systems specifies a maximum depression of 0.04 mbar in such rooms. • The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed. • The air outlet installation must comply with the regulations laid down by the relevant authorities. • When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole. • National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room. • Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood. • If you have any doubts, contact the relevant controlling authority or building inspector’s office. • Since the rule for rooms with fuel burning appliances is “outlet hole of the same size as the ventilation hole”, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood. • If the hood is used in its filtering function, it will operate simply and safely in the above conditions without the need for any of the aforementioned measures. • When the hood is used in its extractor function, the following rules must be followed to obtain optimal operation: — short and straight outlet hose — keep bends in outlet hose to a minimum — never install the hoses with an acute angle, they must always follow a gentle curve. — keep the hose as large as possible (preferably the same diameter as the outlet hole). • Failure to observe these basic instructions will drastically reduce ...

Ce manuel est également adapté pour les modèles :
Ventilateurs - U24211 EFT 530 (516.87 kb)
Ventilateurs - U24211 EFT 635 (516.87 kb)
Ventilateurs - U24211 EFT 535 (516.87 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories