a 36” range would require a minimum 300 cfm • For an Island Style Range Hood: - 150 cfm per foot of hood width • i.e. a 36” range would require a minimum 450 cfm Note: Local building codes, as well as any recommendations provided by the range and range hood manufacturers, should be consulted before making a fan selection. H HHe eel llp ppf ffu uul ll T TTi iip pps ss • Prior to selecting product and materials, consult local building codes. • A range hood grease filter, commonly found in pre-fabricated hoods, must be used in conjunction with AXC fans. • AXC fans may be mounted at any angle. • AXC fan sound levels decrease as the installation distance from the range hood increases. 3 P PPe eer rrf ffo oor rrm mma aan nnc cce ee D DDa aat tta D DDaai iim mme een nns ssi iio oon nna aal ll D DDa aat tta aa MODEL WATTS AMPS RPM dBA* CUBIC FEET PER MINUTE 0”SP 1/8”SP 1/4”SP 3/8”SP 1/2”SP 3/4”SP 1”SP 11/4”SP11/2”SP 2”SP 3”SP AXC100A 55 0.57 1750 44 106 99 93 87 80 68 55 39 AXC100B 85 0.69 2400 54 152 146 139 131 124 106 82 66 33 AXC125A 62 0.58 1650 36 159 127 100 82 68 34 AXC125B 85 0.70 2350 53 212 185 162 145 128 79 32 AXC150A 80 0.75 2500 54 247 225 202 178 161 132 92 50 AXC150B 72 0.73 2580 55 309 271 237 202 171 132 107 88 15 AXC200A 72 0.72 2550 56 418 397 366 339 306 233 174 110 56 AXC200B 160 1.52 2700 60 636 618 557 521 494 412 353 271 190 78 AXC250 250 1.94 2650 63 695 659 610 541 500 359 279 197 125 41 AXC300A 190 2.07 2650 68 865 824 765 736 677 553 459 365 283 124 AXC300B 345 2.78 2765 74 1198 1165 1052 981 945 796 615 453 363 178 65 AXC355A 334 2.88 1360 57 1325 1220 1105 985 860 688 550 400 238 AXC355B 830 7.81 2900 77 1400 1375 1360 1335 1285 1220 1135 1075 1000 880 675 MODEL D (in.) d (in.) a (in.) B (in.) WT (lbs) AXC100A 9.5 3.9 1.0 8.3 6.5 AXC100B 9.5 3.9 1.0 8.3 6.5 AXC125A 9.5 4.8 1.0 8.3 6.5 AXC125B 9.5 4.8 1.0 8.3 6.5 AXC150A 9.5 5.8 1.0 8.3 6.5 AXC150B 13.2 5.8 1.0 9.1 11.0 AXC200A 13.2 7.8 1.0 9.1 11.0 AXC200B 13.2 7.8 1.0 9.1 11.0 AXC250 13.2 9.8 1.0 9.1 11.0 AXC300A 15.9 11.8 1.2 11.8 18.0 AXC300B 15.9 11.8 1.2 11.8 20.0 AXC355A 19.0 14.0 1.5 15.7 26.0 AXC355B 19.0 14.0 1.5 15.7 31.0 * The sound pressure level dBA has been measured in accordance with the international standard ISO 3744. It is the average free field value taken at a radius of 1 meter from the fan, fully ducted, and located above a reflecting plane. At present, there is no standard for sone level testing of remote mounted fans. Sound levels can be affected by the type of duct used, size of duct, distance of the fan from the interior grille/diffuser, and other pertinent factors. Sound tests that do not consider these factors are irrelevant. A AAd ddd ddi iit tti iio oon nna aal ll C CCF FFM MM P PPr rro ood ddu uuc cct tts ss CXCX CompleteComplete Air Purification SystemsAir Purification Systems AeroFanAeroFan Superior Bathroom Fans AeroFan Superior Bathroom Fans DVKDVK Dryer Booster Kits DVKDryer Booster Kits EXT External Mount Duct Fans EXTEXT External Mount ...
Ce manuel est également adapté pour les modèles :Ventilateurs - AXC355A (541.04 kb)
Ventilateurs - AXC125B (541.04 kb)
Ventilateurs - AXC355B (541.04 kb)
Ventilateurs - AXCAXC (541.04 kb)