|
Facilité d'utilisation
The heating elements will not function until the fan is operating. The switches marked ‘I‘ and ‘II’ control the heating elements. The switch marked ‘I’ controls the 800W element. The switch marked ‘II’ controls the 1600W element. When both switches are ON 2400W heat output is available. Operation of Thermostat 1. The heater incorporates a variable thermostat which is controlled by a knob situated on the top right hand side of the front panel. The knob is marked *, 1 - 6, MAX, representing a temperature range of 5°C to 30°C. Lowest setting provides frost protection level. 2. Turn thermostat knob to maximum. When the room has reached the desired comfort level turn back the knob until the thermostat just ' clicks ' off. If the knob is left in this position the room temperature will be maintained automatically at the chosen level. Remember If, when the heater is switched on, the room temperature is above that selected on the thermostat knob the heater will not operate. This is as it should be, and the thermostat is performing its function correctly. Should a higher temperature be required than the one selected, then it will be necessary to turn the thermostat knob to a higher setting to bring the heater into operation. Mains Indicator Neon Lens Located at the bottom left of the front panel, the ‘mains indicator neon lens’ is to indicate when there is electrical supply to the heater and comes on when the fan switch, on the remote switch assembly is selected. Cleaning & User Maintenance WARNING: DISCONNECT SUPPLY before carrying out maintenance. General Cleaning External appearance can be maintained by wiping occasionally with a damp cloth; for stain removal, a weak soap solution can be applied, then wipe dry. Internal Cleaning & Maintenance To help prevent the build up of dust and fluff in the heater it is advisable to apply the soft brush attachment of a vacuum cleaner to the grille occasionally (fig. 1). From time to time it may be necessary to remove the heater from the furniture unit so that the interior of the heater and the heater compartment can be cleared of any accumulated dust or fluff by means of a vacuum cleaner (fig. 2). To remove, unscrew the six fixing screws and withdraw the appliance from the plinth. To gain access to the inside of the appliance remove the screws securing the top cover. Clean the interior of the heater using the soft brush attachment of a vacuum cleaner, taking care not to damage the fan. Refit the top cover. The interior compartment of the furniture unit should also be cleared of dust and fluff using the vacuum cleaner nozzle (fig. 3). Remount the heater in the plinth ensuring the rear support bracket is still adjusted correctly. The electricity supply to the heater can now be switched back on. Safety – overheat protection For your safety, this appliance is fitted with a thermal cut-out. In the event that the product overheats, the cut-out switches the heater off automatically. To bring the heater back into operation, remove the cause of overheating, then turn off the electrical supply to the heater for a few minutes. When the heater has cooled sufficiently reconnect and switch on the heater. If the cut-out operates repeatedly, contact your supplier Procedure for resetting the cut-out; A. Disconnect the electricity supply to the appliance either by switching off at the isolating switch panel. B. Determine what has caused the cut-out to operate and rectify. (Note : This should only be undertaken by competent persons with experience of repairing electrical appliances and in full knowledge of the possible hazards involved ). C. After a short time delay to allow the appliance to cool down, all that is required to return the heater to normal operation is to switch the electricity supply back on. Replacing 13amp fuse The 13amp fuse must be ASTA approved to BS1362. The fuse may be replaced by pulling out the fuse holder, marked ‘fuse’, on the remote switch assembly until the fuse is dislodged. The new fuse should then be located and held in position while the fuse holder is pushed back into position. Circuit Diagram After Sales Service Your Dimplex base unit fan heater is guaranteed for two years from date of purchase. We undertake to exchange or repair free of charge within this period any part found to be defective due to a manufacturing fault. This guarantee in no way prejudices your rights under common law. Should you require after sales service, please get in touch with the supplier through whom you purchased the appliance, or your nearest service agent. Please do not initially return a faulty appliance or part of an appliance to us as this may result in transit damage and / or delay in providing service. Let us know your difficulty, quoting the model number and series letter of the appliance. We will then take the appropriate action. This product complies with the European Safety Standard EN60335-2-30 and the European Standard for Electromagnetic Compatibility (EMC) EN55014, EN6...
Ce manuel est également adapté pour les modèles :Ventilateurs - BFH24RB, BFH24RS, BFH24R (117.61 kb)