Instructions Zephyr, Modèle AK8000AS

Fabricant : Zephyr
Taille : 379.36 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


INSTALLATION MOUNT HEIGHTS DUCTING (AK8000AS, AK8100S, AK8200S) Min 24"-Max 32" 36" Minimum mount height between range top to hood bottom should be no less than 24". Maximum mount height should be no higher than 32". It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire haz- ard; while hoods mounted too high will be hard to reach and will loose its performance and efficiency. If available, also refer range manufacturer's height clearance requirements and recom- mended hood mounting height above range. A minimum of 6" round or 3-1/4” x 10"rectangular duct must be used to maintain maximum air flow efficiency for AK8000/AK8100 and 8” minimum must be used for AK8200. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Minimum clearance of 24”hood above range height. Maximum clearance 32" hood above range height. Minimum Duct Size: Round: 6" minimum for AK8000AS/AK8100S 8" minimum for AK8200S Rectangular: Requires an adapter. Readily available at most hardware stores. Also use calculation (on right) to compute total available duct run when using elbows, transitions and caps. ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size from 6" to 7” or 8" . If a reducer is used, install a long reducer instead of a pancake reducer. Reduce duct size as far away from opening as possible. If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible. Duct Run Calculation: Maximum run AK8100 (6" or 3-1/4” x 10") AK8200 (8”) AK8000 100 FT Deduct: each 90 Elbow used 15 FT each 45 elbow used 9FT each 6" to 3/14 x 10" transition used 1FT each 3/14 x 10" to 6" each 3/14 x 10" to 6" transition used 5FT Side Wall Cap w/ damper 30 FT Roof Cap 30 FT e.g.- 1 roof cap, 2x90 elbows, 1 45 elbow used: =30' + 30' + 9' =69' used, 31' available for straight duct runs. Page 1 INSTALLATION INSTALLATION DUCTING SPECIFICATIONS Twister (AK8000AS) WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside. Use Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape. Some Ducting Options: side wall cap w/ gravity damper side wall cap w/ gravity damper Soffit or crawl space Roof Pitch w/ Flashing & Cap 1-5/32” 10-11/16” 5-15/16” 10-5/16”11-13/16” 27-9/16”26-19/32” 5” 9-27/32” 1-1/16” 11-13/16” 4-3/32” 1-1/4” 3-3/4” BACK FRONT C/L 10-5/8” (cut out) 26-7/8” (cut out) = cut out dimension cut out dimension Page 2 Page 3 INSTALLATION SPECIFICATIONS 10-5/16” 26-19/32” 11-3/16” 27-9/16” 6" C/L 1-3/8” 5-1/8” 1/2" Elec. K.O. 2-3/8" = cut out dimension cut out dimension Tornado 1 unit (AK8100S) INSTALLATION Page 4 Page 5 9-27/32” 27-9/16” 11-3/16” SPECIFICATIONS 15-9/32” 16-3/16" 2” 2-13/16" 34-7/16 8" 1/2"Elec. K.O. 16-3/16" C/L = cutout dimension cut out dimension Tornado 2 unit (AK8200S) 33-7/16" 34-7/16” 7-7/8” 10” 10-5/8” (cut out) 26-7/8” (cut-out) 33-1/2” (cut out) 15-3/8” (cut out) INST ALLA TIO N CONTROLS & FEATURES INSTALLATION Locking clip Controls Power supply cableEntry into range hood Ductwork Front View Attach 2 screws to each long side of AK8100/AK8200 Side View wood blocking wood frame wood frame wood frame wood frame Mounting the Range Hood 1. Determine and mark the mounting position of the range hood with a pencil. 2. Cut out the opening where the range hood will be installed. 3. Cut out wall or ceiling area for clearance of ductwork. Install ductwork prior to range hood. 4. Determine location for the power supply cable. After drilling access hole, rout the cable into the electrical box of the range hood. Secure with a cable lock and connect to range hood electrical system. 5. Position range hood into location and ensure spring locking clip has locked into position. 6. Fasten wood screws into wood frame opening via the long side. Wood blocking may be necessary if wood frame is too thin. ELECTRICAL WARNING All Ele...

Ce manuel est également adapté pour les modèles :
Ventilateurs - AK8200S (379.36 kb)
Ventilateurs - AK8100S (379.36 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories