Log:
Évaluations - , GPA: ( )

Instructions Broan, Modèle 155 D

Fabricant : Broan
Taille : 978.31 kb
Nom Fichier : 264900EN.pdf

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


AEG - putting words into action. Introduction The hood is supplied as an extractor unit and can also be used with a filtering function by fitting activated carbon filters (special accessory). The unit features two outlet holes, one of which A is located on the top of the unit while the other B is located on the rear. To connect up the hose, you should first fit the bayonet-mounting flange C on the outlet required (if using the top outlet, fix the flange in place using the screw supplied as shown in Fig. 1. Close off the unused hole using the bayonet-fitting caps D. If using the rear hole, open the air passage by removing the partition (E — Fig. 2) Move the lever F to position A — Fig. 3. When connecting up the hood using a telescopic wall pipe, you should preferably using the uninflammable outlet hose No. E 610 899 007 (120 mm 0) from our range of special accessories. Extractor version 23 Filter version The air is filtered and recirculated through the front grille. You will need an original AEG KLF60/80 activated carbon filter for filtering function. (See special accessories). 24 Electrical connections Check that the power supply voltage shown on the rating plate Safety corresponds to the mains supply before proceeding to make any warnings for electrical connections. If the unit is supplied ready-fitted with a electrician plug, it can be connected to any easily accessible socket installed in compliance with the regulations in force. If a fixed connection is required, the hood must be installed exclusively by an electrician registered with the local electrical company. The hood should be installed using an omnipolar switch with contacts that open to at least 3 mm. Fused switches can be used for this purpose (with cartridge fuses that can be extracted from the fuse holder), as can automatic circuit breakers and contactors which open to more than 3 mm. We decline all responsibility for any problems or faults caused by a failure to observe the above instructions. Installing the socket directly above the hood or above the wall unit mounted above the hood offers the following advantages: 1. The socket cannot be seen. 2. The unit can be disconnected whenever required by simply taking out the plug. Electrical connections 230 V - using fixed power supply line with plug. (The unit should only be connected up by an authorized electrician). 25 Specifications Dimensions: Height Width Depth (in mm) 152 599 505 Weight: Net: 10,5 Kg Gross: 11,5 Kg Maximum absorbed power: 360 W Motor absorption: 2 x 140 W Lighting: 2 x 40 W Fan powers (levels), levels in compliance with DIN 44971 Exhausting version: min. 120 m3/h max. 254 m3/h Intensive speed 385 m3/h Recycling version: min. 50 m3/h max. 180 m3/h Intensive speed 206 m3/h Extractor system: 120 mm 0 Montage When used as an extractor unit, the hood must be fitted with a 120mm diameter hose. If the outlet hose is installed in a horizontal position, it must nevertheless be s...

Ce manuel est également adapté pour les modèles :
Ventilateurs - 155 D (978.31 kb)
Ventilateurs - 155 D (978.31 kb)
Ventilateurs - 155 D (978.31 kb)
Ventilateurs - 155 D (978.31 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories