|
Facilité d'utilisation
• FIXING THE DECORATIVE TELESCOPIC FLUE Arrange the electrical power supply within the dimensions of the decorative flue. If your appliance is to be installed in the ducting version or in the version with external motor, prepare the air exhaust opening. Adjust the width of the support bracket of the upper flue (Fig.4).Then fix it to the ceiling using the screws A (Fig.4) in such a way that it is in line with your hood and respecting the distance from the ceiling indicated in Fig.3. Connect the flange C to the air exhaust hole using a connection pipe (Fig.5). Insert the upper flue into the lower flue. Fix the lower flue to the hood using the screws B provided (Fig.5), extract the upper flue up to the bracket and fix it with the screws B (Fig.4). USE • If the apparatus is equipped with the following controls (fig.6A): A = OFF B = SPEED I C = SPEED II D = SPEED III E = LIGHT • If the apparatus is equipped with the following controls (fig.6B): A = LIGHT B = OFF/SPEED I C = SPEED II D = SPEED III E = AUTOMATIC STOP TIMER – 15 minutes F = FILTER SATURATION RESET LIGHT When the “filter saturation” light flashes or comes on without flashing, the anti-grease filters must be washed.When this operation has been completed, press the key (F) to reset it. The “automatic stop timer” delays stopping of the hood, which will continue functioning for 15 minutes at the operating speed set at the time this function is activated. • If the apparatus is equipped with the following controls (fig.6C): A = LIGHT B = OFF C = SPEED I D = SPEED II E = SPEED III F = AUTOMATIC STOP TIMER - 15 minutes • If your appliance does have the INTENSIVE speed function, press key E for two seconds and it will be activated for 10 minutes after which it will return to the previously set speed. When the function is active the LED flashes.To interrupt it before the 10 minutes have - 9 expired press key E again. • By pressing key F for two seconds (with the hood switched off) the “clean air” function is activated. This function switches the appliance on for ten minutes every hour at the first speed. As soon as this function is activated the motor starts up at the first speed for ten minutes, During this time key F and key C must flash at the same time. After ten minutes the motor switches off and the LED of key F remains switched on with a fixed light until the motor starts up again at the first speed after fifty minutes and keys F and C start to flash again for ten minutes and so on. By pressing any key for the exclusion of the hood light the hood will return immediately to its normal functioning (e.g. if key D is pressed the “clean air” function is deactivated and the motor moves to the 2nd speed straight away. By pressing key B the function is deactivated). •The “automatic stop timer” delays stopping of the hood, which will continue functioning for 15 minutes at the operating speed set at the time this function is activated. • If the apparatus is equipped with the following controls (fig.6D): Push-button A = on/off lights switch Push-button B = on/off cooker hood switch. The appliance switches on at speed level 1, If the cooker hood is on depress the push-button for 2 sec. to switch off the cooker hood. If the cooker hood is at speed level 1 it will not be necessary to depress the push-button to switch the cooker hood off. Decreases the motor speed. Display C = indicates the motor speed level selected and activates the timer. Push-button D = switches on the cooker hood. Increases the motor speed. Touching the key at 3rd speed, the intensive function runs for 10', then the appliance go back to work at the original speed. During this function the display blinks. Key E = The Timer times the functions on activation for 15 minutes, after which they are switched off.The Timer is deactivated by re-pressing Key E.When the Timer is activated the decimal point must flash on the display.The Timer cannot be activated if the intensive speed is functioning. The “clean air”function is activated by pressing key E for 2 seconds when the appliance is switched off. This switches the motor on for 10 minutes every hour at the first speed. During functioning a rotary movement of the peripheral segments must be visualised on the display. When this time has passed the motor switches off and the fixed letter “C” must be visualised on the display until the motor re-starts after 50 minutes for another 10 minutes and so on. Press any key apart from the light keys to return to normal functioning. Press key E to deactivate the function. • If the apparatus is equipped with the following controls (fig.6E): A = LIGHT B = OFF/SPEED I C = SPEED II D = SPEED III E = AUTOMATIC STOP TIMER – 15 minutes - 10 L = LOGIC The “automatic stop timer” delays stopping of the hood, which will continue functioning for 15 minutes at the operating speed set at the time this function is activated. • AUTOMATIC LIGHT PLUS MOTOR OPERATION Ensure that the cooker hood is in the OFF position and depress the l...
Ce manuel est également adapté pour les modèles :Ventilateurs - Range Hood MC-I-6090 (918.78 kb)