Log:
Évaluations - 2, GPA: 4 ( )

Instructions Balance, Modèle HEALTH O METER 500KL

Fabricant : Balance
Taille : 1.86 mb
Nom Fichier : 8ce89df6-49ec-4ec5-a24e-7f83ff857dc3.pdf
Langue d'enseignement: enesfr
Aller à la télécharger



Facilité d'utilisation


Please read this manual carefully and keep it handy for ready reference. Merci d’avoir achete ce produit. Veuillez lire attentivement ce manuel et le garder a portee de main pour pouvoir le consulter a tout moment Gracias por la adquisicion de este producto. Lea por favor este manual cuidadosamente y mantengalo a su alcance para una pronta referencia. ENGLISH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 FRANCAIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 ESPANOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 TABLE OF CONTENTS CAUTION AND WARNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SCALE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 STORAGE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 OPERATION INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 WARRANTY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 CAUTION AND WARNING To prevent injury and damage to your scale, please follow these instructions very carefully • Do not transport the scale while the platform is loaded. • For accurate weighing the scale must be placed on a flat, stable surface. • For accurate weighing, verify proper operation according to the procedure described in this manual before each use. • Do not use in the presence of flammable materials. • Operating at other voltages and frequencies than specified could damage the equipment. • If the “LOW BAT” indicator activates, for accurate weighing replace the batteries or connect the scale to an AC power source as soon as possible. • Only manufacturer’s qualified personnel shall service this scale. This equipment has been tested and found to comply with the EMC limits for the Medical Device Directive 93/42/EEC (EN 55011 Class __ and EN 60601-1-2). These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. The equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference with other devices, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving device. • Increase the separation between the equipment. • Connect the equipment into an outlet on a circuit different from that to which the other device(s) is connected. • Consult the manufacturer or field service technician for help. DEFINITION OF SYMBOLS +50C Temperature range AC to DC power supply Attention, Consult Accompany Documents 12V DC, 100mA -10C Humidity range ++ DC Connector Polarity Type BF Applied Parts 10%-95% RH Atmospheric pressure range AC to DC power supply 1060hps 500hps SCALE SPECIFICATIONS Capacity and resolution 500lb x 0.2lb / 220kg x 0.1kg Power Requirements Adapter Model ADPT31* 120VAC - 12VDC 60Hz 100mA or 6 - AA cell 1.5 V batteries Environmental Platform Dimensions: Operating temperatures: 50.F to 104.F / 10°C to 50°C Atmospheric Pressure: 500hPa - 1060hPa Humidity: 10% - 95% RH 16 1/2" x 14" x 2 1/2" / 42.3 cm x 35.6 cm x 5.8 cm Scale Dimensions 21" x 14 3/4" x 53 1/2" / 53.5 cm x 37.5cm x 136cm *WARNING: For use with AC Adapter Model CSD1200100U-31/ADPT31 only. STORAGE SPECIFICATIONS Complies with C22.2 No. 601.1-M90 and UL Std No. 60601-1. Type BF applied parts. Internally powered. Equipment not suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide. Storage Temperatures: 32.F to 122.F / 0°C to 50°C Humidity: 10% - 95% RH Atmospheric Pressure: 500hPa - 1060hPa 2 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS BALANCES.COM MODEL 500KL INSTALLING BATTERIES - Use only AA alkaline batteries. 1. The battery compartment is located behind scale head. 2. Place 6 new AA batteries into battery compartment. Make sure the '+' and '-' are positioned correctly, as shown on the bottom of the battery compartment. Replace the batteries when the display reads 'LobAt'. 3. Install batter cover. 4. 120V AC adapter included ( model ADPT31). NOTE: Dispose used batteries in accordance to your country’s national requirements. MAINTENANCE AND CLEANING -Before first use and after periods of non-use, check the scale for proper operation. Disconnect the scale from the AC power source. 1. To clean the scale, wipe the outside of the scale with a soft cloth and mild detergent. Do not use abrasive cle...

Ce manuel est également adapté pour les modèles :
Balance - HEALTH O METER E 500KL (1.86 mb)
Balance - HEALTH O METER O 500KL (1.86 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories