Log:
Évaluations - 3, GPA: 4 ( )

Instructions Panasonic, Modèle AWML600

Fabricant : Panasonic
Taille : 1.04 mb
Nom Fichier : AWML600.PDF
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


To assure continued compliance follow the attached installation instructions and do not make any unauthorized modifications. This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. -For CANADA-, This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la class A est conforme à la norme NMB-003 du Canada. CAUTION: Do not install or place this unit in a bookcase, built-in cabinet or any other confined space in order to maintain adequate ventilation. Ensure that curtains and any other materials do not obstruct the ventilation to prevent risk of electric shock or fire hazard due to overheating. Note: The rating plate (serial number plate) is on the bottom of the unit. ii ii indicates safety information. Contents Introduction ...............................3 Parts and Their Functions ...................4 Remote Control Unit Settings.................5 Connections...............................6 Operating Precautions ......................9 Specifications ............................10 Introduction • This Multiplex Adaptor converts the DC power (approx. 100 V) from the remote control unit (RCU) into DC 12 V and supplies it to the pan/tilt head and camera. Furthermore, it can separate or multiplex the signals which are listed below. • Video signals • Genlock signals • Control signals of the camera • Control signals of the lens • Control signals of the pan/tilt head • The unit and RCU can be connected using a single coaxial cable (5C-2V, 300 m max. length, N-type connectors used). The unit and pan/tilt head are connected by the cable supplied with the unit. • The unit incorporates a protection circuit which is activated when any problem (short-circuiting, broken wire or non-connection) has occurred in the coaxial cable or an error has been made in operation. For details on how to release the protection circuit after it has been activated, refer to “Operating precautions" (page 9). • An RS-232C/RS-422 converter is required if this unit' is to be used to construct a pan/tilt head system. Consult your dealer with regard to the RS-232C/RS-422 converter and the connection cables. 3 Parts and Their Functions Front panel Panasonic OPERATE Q Multiplex Adaptor AW-ML l£ \n Rear panel o OPERATE LED This LED lights several seconds after the power is supplied from the WV-RC700A remote control unit (RCU). When it lights, control can be exercised from the AW-RP301 pan/tilt control panel, and all the operations of the pan/tilt head and camera including turning their power on and off can be performed. The OPERATE LED may not light if the power is turned back on within 2 seconds immediately after the RCU’s power switch was set to OFF. Wait at least two seconds before turning the power back on. ©GND connector This is the chassis GND of the unit. ©DATA connector The unit is connected here to the AW-PH300A pan/tilt head when the pan/tilt head or camera is to be controlled from an external component using the RS-232C interface (baud rate: 9600 bps) instead of using the controls on the pan/tilt control panel. (Optional cable: AW-CA28T9) The pan/tilt head or camera cannot be controlled by connecting a control component, etc. with an RS-232C connector to this connector. Consult your dealer if the pan/tilt head or camera is to be controlled using the RS-232C connector from an external component. 0MPX connector The MPX connectors on this unit and the RCU are connected using the coaxial cable. O CONTROL connector The unit is connected here to the AW-PH300A pan/tilt head using the cable supplied with the unit. 4 Remote Control Unit Settings CAUTION These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Before proceeding with the connections, set the switches on the boards incorporated inside the WV-RC700A remote control unit (RCU). Unless these switches are set, it will not be possible to exercise control from the AW-RP301 pan/tilt control panel. • Set switch SW2 on the MOD UNIT board to INCOM. (Factory setting: INCOM) MOD UNIT board VIDEO UNIT board MOD SW2 AUDO d INCOM • Set switch SW2 on the VIDEO UNIT board to MODEM and switch SW1 to LOW. (Factory s...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories