Log:
Évaluations - 3, GPA: 4.3 ( )

Instructions Panasonic, Modèle AJD780P

Fabricant : Panasonic
Taille : 1.22 mb
Nom Fichier : AJD780P.PDF
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


The recording operation is stopped if this error has occurred during recording. Warning messages (See warning message table) When a warning occurs in this unit, an error number appears at the counter display and warning message is displayed. When multiple warnings occur, the warning with the highest priority is displayed. -38- Warning Priority Error No. TV monitor display* Description High * E-03* (Err-03) SDI SIG This message appears when the input signal is an SDI signal. The recording operation is stopped if the error has occurred during recording. E-04* (Err-04) UNKNOWN SIG This message appears when the input signal does not comply with the DVCPR025 format. The recording operation is stopped if the error has occurred during recording. 1 J 1 E-06* (Err-06) NOT 4X SIG During recording, if the input signals are not 4X speed signals, this message appears, and the recording operation is stopped. 1 1 1 1 1 1 E-07* (Err-07) SDTI HIGH ERROR This message appears when errors which cannot be corrected have occurred in the input signal. The recording operation is stopped if the error has occurred during recording. 1 r 1 \ 1 E-10* (Err-10) FAN STOP This message appears when the fan motor has been shut down. 1 1 1 1 E-00* (Err-00) SERVO NOT LOCKED This message appears when the servo has been disengaged for 3 or more seconds during 4x speed playback or 4x speed recording. 1 1 1 1 1 E-01* (Err-01) LOW RF This message appears when it is detected that the envelope level has remained at approximately one-third of its normal level for 1 or more seconds during 4x speed playback. 1 ▼ Low E-02* (Err-02) HIGH ERROR RATE This message appears when the error rate has deteriorated and concealment or interpolation is applied to the video or audio playback signals. * This display appears when the DIAG button is pressed and the warning information is checked. AUTO OFF mode The following error number flashes on the counter display section. Error No. TV monitor display Descriptions VTR operation (VTR measures) E-20 DEW When condensation is detected, the error no. display flashes, and the unit goes into EJECT mode. The drum rotates after the cassette tape is ejected to remove condensation. When the condensation has been removed, the error no. display disappears and the VTR may be used. 1) The drum rotates as soon as condensation is detected when the unit is in EJECT mode. 2) When condensation is detected while a cassette tape is inserted, drum rotation stops, the cassette tape is ejected and the drum rotation begins again. EJECT E-29 FRONT LOAD MOTOR The cassette does not move up even when 6 seconds have elapsed since the VTR was transferred to the eject mode. After inserting the cassette, the unit will go to EJECT mode if cassette is not loaded after six seconds. Stop (POWER OFF-ON) E-31 LOADING MOTOR The unloading operation is not completed within 6 seconds. The unit will go to EJECT mode (unloading) if the loading operation is not completed within six seconds. Stop (POWER OFF-ON) E-35 SERVO CONTROL ERR There is no response from the servo microcomputer for 1 or more seconds. Stop (POWER OFF—ON) -39- Error messages Error No. TV monitor display Descriptions VTR operation (VTR measures) E-36 SERVO ERROR Only the servo microcomputer was reset in an instantaneous power failure. Stop (POWER OFF—*ON) E-37 SERVO COMM ERROR The servo microcomputer does not follow the instructions of the system control micorcomputer even when 10 seconds have elapsed. Stop (POWER OFF-ON) E-51 FRONT LOAD ERROR The take-up reel has been rotating idly for a fixed period of time white the start/end processing operation during loading {half position) is being performed. Stop (POWER OFF-ON) E-52 W-UP REEL NOT ROTA After the cassette has been inserted, the tape take-up reel has not wound up the tape while the total tape amount is not detected and while the tape is traveling. Stop (POWER OFF-ON) E-53 WINDUP ERROR After the total tape amount has been detected, the amount of tape wound up on the take-up reel and the amount of tape supplied by the supply reel differ to an abnormal extent while the tape is traveling. Stop (POWER OFF-ON) E-55 UNLOAD ERROR The tape has not been wound up during unloading. Stop (POWER OFF-ON) E-57 S-FF/REW TIMEOVER The start/end processing operation is not completed even after 10 or more seconds have elapsed. Stop (POWER OFF-ON) E-59 DRUM ROTA TOO SLOW The cylinder motor speed is abnormally low. Stop (POWER OFF-ON) E-60 DRUM ROTA TOO FAST The cylinder motor speed is abnormally high. Stop (POWER OFF-ON) E-61 CAP ROTA TOO SLOW The capstan motor speed is abnormally low. Stop (POWER OFF-ON) E-64 S REEL TOO FAST The supply reel motor speed is abnormally high. Stop (POWER OFF-ON) E-67 T REEL TOO FAST The tape*up reel motor speed is abnormally high. Stop (POWER OFF-ON) E-69 T REEL TORQUE ERR An abnormal torque applied to the take-up reel motor is detected. Stop (POWER OFF-ON) E-70 S REEL TORQ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories