|
Instructions Chamberlain, Modèle Security+ 3900PLD
Fabricant : Chamberlain Taille : 1.98 mb Nom Fichier : 114A3593.pdf
Langue d'enseignement:
|
|
|
|
Aller à la télécharger
Facilité d'utilisation
¦ The door WILL NOT CLOSE unless The Protector System® and cable tension monitor are connected and properly aligned. ¦ Periodic checks of the operator are required to ensure safe operation. ¦ The model number label is located behind the hinged door of your operator. ¦ Do NOT exceed 10 complete cycles of door operation per hour. 2 YEAR WARRANTY Serial # Installation Date TABLE OF CONTENTS Introduction 2-5 Safety symbol review and signal word review . . . . . . . . . . 2 Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Preparing your door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Tools needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Carton inventory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Hardware inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Assembly 6 Attach the collar to the operator. . . . . . . . . . . . . . . . . . . . .6 Attach mounting bracket to the operator . . . . . . . . . . . . . .6 Installation 7-16 Installation safety instructions . . . . . . . . . . . . . . . . . . . . . .7 Position the operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Attach the emergency release rope and handle . . . . . . . . 8 Install power door lock (Not Provided). . . . . . . . . . . . . . . .8 Attach the cable tension monitor (Required) . . . . . . . . . . . 9 Install the single button control station. . . . . . . . . . . . . . .10 Install the light (Not Provided) . . . . . . . . . . . . . . . . . . . . .11 Electrical requirements. . . . . . . . . . . . . . . . . . . . . . . . . . .12 Mount the Standby Power Unit (SPU) (Not Provided). . .13 Install The Protector System®. . . . . . . . . . . . . . . . . . . 14-16 Adjustment 17-20 Program the travel limits . . . . . . . . . . . . . . . . . . . . . . . . .17 Set the force. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Test the safety reversal system. . . . . . . . . . . . . . . . . . . .19 Test The Protector System®. . . . . . . . . . . . . . . . . . . . . . .19 Test cable tension monitor. . . . . . . . . . . . . . . . . . . . . . . .20 To open door manually . . . . . . . . . . . . . . . . . . . . . . . . . .20 INTRODUCTION Safety Symbol Review and Signal Word Review Operation 21-25 Operation safety instructions . . . . . . . . . . . . . . . . . . . . . .21 Using your door operator. . . . . . . . . . . . . . . . . . . . . . . . .21 Care of your operator. . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Having a problem? (Troubleshooting) . . . . . . . . . . . . 23-24 Diagnostic Chart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Programming 26-28 To add or reprogram a hand-held remote control (Not Provided) . . . . . . . . . . . . . . . . . . . . .26 To erase all codes from motor unit memory . . . . . . . . . .26 3-Button remote . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 The remote control battery. . . . . . . . . . . . . . . . . . . . . . . .26 To add, program or change a keyless entry PIN (Not Provided). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Programming remote light (Not Provided) . . . . . . . . . . . . 28 Repair Parts 29 Installation parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Motor unit assembly parts . . . . . . . . . . . . . . . . . . . . . . . .29 Accessories 30 Notes 31 Repair Parts and Service 32 This door operator has been designed and tested to offer safe service provided it is installed, operated, maintained and tested in strict accordance with the instructions and warnings contained in this manual. Mechanical Electrical When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully. When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your garage door and/or the garage door operator if you do not comply with the cautionary statements that accompany it. Read them carefully. 2 Planning Survey your area to see if any of the conditions below apply to your installation. Additional materials may be required. You may find it helpful to refer back to this page as you proceed with the installation of your operator. Depending on your requirements, there are several installation steps which may call for materials or hardware not included in the carton. This operator is compatible with: • Doors that use a torsion bar, springs and a door no more than 14' (4.2 m) high. • 4"-6" (10 cm - 15 cm) drums, not to be used on tapered drums over 6" (15 cm). • High lift and standard lift sectional doors up to 14' (4.2 m) high. • Doors up to 18' (5...
Écrivez votre propre critique du dispositif
|
|