Fabricant : Chamberlain
Taille : 578.39 kb
Nom Fichier : 598-1163-01.pdf
|
Facilité d'utilisation
• Automatically turns lighting off. • Photocell keeps the lighting off during daylight hours. • LED indicates motion was sensed (day or night). • Additional energy savings with compact fluorescent bulbs. This package includes: Lamp Holders Rubber Plug Plastic Hanger SensorCover Plate Light Control 2 Wire Connectors (3 sizes included) Mounting Bolt Mounting Strap Gasket 2 Compact 6 Screws Fluorescent Bulbs Requirements • The Light Control requires 120-volts AC. • If you want to use Manual Mode, the control must be wired through a switch. • Some codes require installation by a qualified electrician. • This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations. • Note: This product is not recommended for use where the outside temperature is below -10° F. OPERATION Mode: On-Time: Works: Day Night Test 5 Sec x x Auto 1, 5, 10 min. x Manual Until Dawn* x * resets to Auto Mode at dawn. Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate. TEST 10 5 1 TEST ON-TIMEPut the ON-TIME switch on the bottom of the sensor in the TEST position. AUTO ON-TIME 10 5 1 TEST Put the ON-TIME switch in the 1, 5, or 10 minute position. Note: Although the 1 minute mode can be used, the 5 or 10 minute mode is recommended for best operation and performance when using compact fluorescent bulbs. MANUAL MODE Manual mode only works at night because daylight returns the sensor to AUTO. Flip the light switch off for one second 1 Second OFF then back on to toggle between AUTO then... and MANUAL MODE. Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position. ... back on. Mode Switching Summary TEST Move ON-TIME Switch to 1, 5, or 10 minutes AUTO Flip light switch off for one second then back on* MANUAL MODE * If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode. © 2004 DESA Specialty Products™ 598-1163-01 . Route the Light Control’s wires through the large INSTALLATION gasket holes. For easy installation, select an existing light with a wall . Twist the junction box wires and fixture wires together switch for replacement. as shown. Secure with wire connectors. 123456789012345678123456789012345678 Wall Mount Eave Mount For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. For eave mount only: WIRE THE LIGHT CONTROL. .Swing the sensor head towards the clamp screw joint. If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done. .Then rotate the sensor head clockwise 180°so the controls face down. Controls Controls Controls Clamp Screw . Turn power off at the fuse or circuit breaker. . Remove the existing light fixture. . Install the mounting strap as shown using two screws that fit your junction box. . The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap. MOUNT THE LIGHT CONTROL. White to White Black to Black Junction box ground wire to green ground screw on fixture. Gasket Mounting Strap Mounting Bolt Rubber Plug . Align the Light Control cover plate and cover plate gasket. Secure with the mounting bolt. . Push the Rubber Plug firmly into place. . If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant. Lock Nut To avoid water damage Keep lamps at least 1" (2.5 cm) from the sen- sor. Do not allow the Push Rubber Plug Firmly into Place. Lens Holes for Lamp Cover Tabs and electrical shock, lamps to block the lens. keep lamp holders 30° below horizontal. . Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the lamps, do not overtighten. . Install the lamp covers. Align the tabs on the lamp covers with the holes on the lamp holders. Gently press lamp covers until the tabs snap into the holes on the lamp holders. 2 598-1163-01 TEST AND ADJUSTMENT . Turn on the circuit breaker and light switch. NOTE: Sensor has about 1 1/2 minutes warm up period before it will detect motion. When first turned on, wait about 1 1/2 minutes. . Turn the RANGE control to the mid position and the ON-TIME control to the TEST position. ON-TIME RANGE 10 5 1 TEST MAXMIN RANGEON-TIME 10 5 1 TEST MINUTES MIN MAX Bottom of Sensor Avoid aiming the control at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas where pets or traffic may trigger the control. • Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the s...
Ce manuel est également adapté pour les modèles :Vidéo - SH-5710 (578.39 kb)