Check that the system water water pressure gauge G reads at least 0,5 bar. Check the lock---out signal lamp E. If it is illuminated press the boiler reset button D to restart the ignition sequence. Hot water but no heating Check that the programmer and room thermostat (if fitted) are both calling for heat. Heating but no hot water Check that cold water flows out of the taps at a minimum rate of 3.5 litres per minute (or 1 pint in 10 seconds or less). If not, look for stop valves not fully open. If these simple checks fail to solve the problem, or the problem recurs, consult your service engineer. (button) Points for Boiler User Note. In line with our current warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer. Troubleshooting – Typical Non Product Faults Problem Solution Boiler is not working for central heating or hot water · Is there power to the boiler i.e. is the left hand side green LED (A) alight and flashing every 4 seconds. If not this is not a boiler fault – contact the installer · Check pressure gauge on boiler shows a minimum of 1 bar If not re-pressurise via the filling loop to 1 bar (if unsure contact your installer), turn off the tap on the filling loop and press the reset button (D) to reset the boiler. If unable to do so or if the pressure continues to drop after filling then contact your installer · Is the lockout signal lamp (E) alight – Press boiler reset button (D) – If boiler still does not fire contact the installer Boiler goes through ignition sequence but will not fire for either central heating or hot water and then goes to ignition lockout · Check gas supply (try another gas appliance cooker/fire etc) If no gas supply then this is not a boiler fault – Contact the gas supplier Fan & pump run continuously but there is no attempt at ignition · Check that the air pressure switch test caps, on top of the boiler, are fitted correctly. Mini C Only Operating for hot water but will not operate for central heating · Check that integral programmer is set to an ‘on’ period and the function switch is set to ‘auto’ – If it still does not operate contact your installer · If fitted with an external programmer check that the central heating channel is set at an ‘on’ period – If it still does not operate contact your installer. · Check the room thermostat is set at the required temperature – Test the room thermostat by turning fully up – If this does not respond contact your installer · Check the radiator temperature control (C) is set at the winter setting for central heating. The nature of all combination boilers is to heat up water directly from the incoming mains water supply directly through the boiler to supply domestic hot water at ...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - MINI C28 (194.78 kb)
Chauffe-eau - MINI S24 (194.78 kb)
Chauffe-eau - MINI S28 (194.78 kb)
Chauffe-eau - MINI C32 (194.78 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories