CONTINUE GENERAL INSTALLATION 4. Connect both 1/2. NPT water lines (FIG 2) hot water outlet female and cold water inlet female and 3/8. flared LP gas line to the water heater (FIG 9). a. Allow flexibility in water and gas lines so you can pull unit forward through wall one inch past skin. b. Seal gas line entrance opening (FIG 9) by sliding grommet (9-B) onto 3/8. tubing (9-D) before flaring tubing (9-E). Pull gas line and grommet through opening in housing (9-A). Connect flare fitting (9-C) and press grommet into opening. If gas line tubing is already flared, cut grommet on one side. Place split grommet over gas line and press it into opening. c. Always use pipe lubricant on threads when connecting hot and cold water couplings. A suitable plastic fitting is recommended. CAUTION PRODUCT DAMAGE • Do not lift, pull, push or misalign main burner tube (FIG 3-F). 5. Erect side walls and cut opening. See chart and FIG 1. Frame with 2x2 lumber (or equivalent). CUTOUT (FIG 1 & 2) CAPACITY CUT OUT DIMENSION DEPTH Gallon 1-A 1-B 2-C 4 - 6 12-5/8. 16-1/4. 17-5/8. 10 15-3/4. 16-1/4. 20-5/8. MINIMUM CLEARANCE FROM COMBUSTIBLE CONSTRUCTION Sides: 0. Top: 0. Back: 0. Bottom: 0. 6. Bend all flanges 90° along scored lines (FIG 3-A). 7. To prevent water leaks caulk thoroughly around opening, including bend slots. Butyl Tape (1-1/3.x1/8.) may be substituted for caulking material. 8. Push unit against caulking, secure 4-corner brackets (FIG 3-B) to coach with No. 8 - 3/4. round head screws (not furnished) or equivalent. Complete the installation by inserting the same type of #8 screws in the holes provided around the flange of the water heater housing. Check all gaskets, they must adhere to the pan creating an air tight seal. 9. Attach access door. a. Snap hinge pin (FIG 3-C) into clip (FIG 3-D). b. Slide cover (FIG 3-E) onto hinge pin. c. Slide hinge pin into cover, snapping into clip at same time (FIG 3-D). NOTE: To remove hinge pin, support access cover and apply force to corner of hinge pin. 10. Disconnect unit and its individual shut-off valve from gas supply line during any pressure testing of system in excess of 1/2 PSIG (3.4 kPa, 14. water column [W.C.]). DO NOT set inlet pressure higher than maximum indicated on rating plate of gas valve (13. W.C.). Isolate unit from gas supply line by closing its individual manual shutoff valve during any pressure testing . 1/2 psig. WARNING FIRE AND/OR EXPLOSION • DO NOT use matches, candles or other sources of ignition when checking for gas leaks. 11. Turn on gas and check water heater and all connections for gas leaks with leak detecting solution. 12. Fill water heater tank, check all connections for water leaks. PRESSURE-TEMPERATURE RELIEF VALVE WARNING EXPLOSION • Valve is not serviceable, it must be replaced. • Tampering with valve will result in scalding injury. • Tampering with valve will void warranty. • DO NOT place a valve, plug or reducing coupling on outlet part of relief valve. THIS VALVE IS A SAFETY COMPONENT AND MUST NOT BE REMOVED FOR ANY REASON OTHER THAN REPLACEMENT. This water heater is equipped with a temperature and pressure relief valve (FIG 3-G) that complies with standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Systems, ANSI Z21.22. If you use a discharge line, do not use a reducing coupling or other restriction smaller than outlet of relief valve. Allow complete drainage of both valve and line. FOR REPLACEMENT PARTS: • DO NOT install anything less than a combination temperature-pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of product of listed equipment or materials, as meeting requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22. Valve must have a maximum set pressure not to exceed 150 psi. • Install valve into opening provided and marked for this purpose on water heater. • Installation must conform with local codes or in the absence of local codes, American National Standard for Recreational Vehicles, ANSI A119.2/NFPA 50IC. • For an external electrical source, ground this unit in accordance with National Electrical Code ANSI/NFPA70. Your ATWOOD PILOT GAS WATER HEATER is now ready for operation. Continue to HOW TO OPERATE YOUR WATER HEATER CONSUMER SAFETY WARNINGS WARNING EXPLOSION OR FIRE • DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • Should overheating occur, or gas supply fail to shut off, turn OFF manual gas control valve to appliance, or turn gas OFF at the LP tank. On ELECTRONIC IGNITION MODEL turn operating switch to OFF position and remove red wire from left hand terminal of ECO switch or turn gas OFF at the LP tank. • Use with LP gas only. • Shut off gas appliances and pilot lights when refueling. • On PILOT RELIGHT MODELS, turn off the ignition module when refueling gasoline tanks or LP tanks. • Turn gas OFF at the LP tank when vehi...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - 4-E (406.42 kb)
Chauffe-eau - 10-E (406.42 kb)
Chauffe-eau - 4-E (406.42 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories