Log:
Évaluations - 3, GPA: 4 ( )

Instructions Desa, Modèle A, C, B

Fabricant : Desa
Taille : 4.3 mb
Nom Fichier : 5cb67427-0d70-4454-6d33-574fc80ea13d.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Make sure material is secure. CAUTION: Do not pick up heater base assembly by burners. This could damage heater. Only handle base assembly by grates. IMPORTANT:Make sure the heater burners are level. If heater is not level, heater will not work properly. For thermostat models, avoid damage to thermostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in mounting bracket. Installation Items Needed • hardware package (provided with heater) • approved flexible gas hose and fittings (not provided) (if allowed by local codes) • sealant (resistant to propane/LP gas, not provided) • electric drill with 3/16" masonry drill bit Note:Install optional GHRCTA Receiver and Hand-Held Remote Control Kit (see Accessories, page 36) before installing gas log heater (Remote-Ready Models Only). See installation instructions included with the kit. 1. Apply pipe joint sealant lightly to male threads of gas fitting (not provided). For Variable Manually-Controlled and Thermostatically- Controlled Models connect approved flexible gas hose to gas regulator of heater (see Figure 11, page 11). For Remote-Ready models connect approved flexible gas hose to inlet side of gas control (see Figure 12, page 11). IMPORTANT:Hold gas regulator with wrench when connecting flexible gas hose (Variable Manually-Controlled and Thermostatically- Controlled Models Only). 2. Locate mounting brackets, bolts, and nuts in hardware package (Variable Manually-Controlled and Thermostatically-Controlled Models Only). Attach mounting brackets to heater base (see Figure 13, page 11). Attach nuts finger tight. 3. Position heater base assembly in fireplace. For more information, visit more information, visit 104415 Forr morre iinfforrmattiion,, viisiitt 1111 INSTALLATION Continued Heater Gas Regulator Flexible Gas Hose (if allowed by local codes) Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator (Variable Manually-Controlled and Thermostatically-Controlled Models Only) Figure 13 - Attaching Heater to Fireplace Floor (Variable Manually- Controlled and Thermostatically-Controlled Models Only) Masonry Screw Mounting Bracket Screw Mounting Bracket Nut Mounting Bracket 4. For Variable Manually-Controlled and Thermostatically-Controlled Models mark screw locations through holes in mounting brackets (see Figure 13). For Remote-Ready Models mark screw locations through holes in front panel of base (see Figure 14). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks. 5. Remove heater base from fireplace. 6. Remove mounting brackets from heater base (Variable Manually- Controlled and Thermostatically-Controlled Models Only). 7. Drill holes at marked locations using 3/16" drill bit. 8. For Variable Manually-Controlled and Thermostatically-Controlled Models attach mounting brackets to fireplace floor using masonry screws provided in hardware package (see Figure 13). Reattach heater base to mounting brackets (see Figure 13). Tighten nuts firmly. 9. For Remote-Ready Models attach base, through holes in front panel of base, to fireplace floor using masonry screws provided in hardware package (see Figure 14). 10. Connect to gas supply. See Connecting To Gas Supply, page 12. INSTALLATION Installing Heater Base Assembly (Cont.) Figure 12 - Attaching Flexible Gas Hose to Heater Gas Regulator (Remote-Ready Models Only) Figure 14 - Attaching Base to Fireplace Floor (Remote-Ready Models Only) Gas Control Flexible Gas Hose (if allowed by local codes) Masonry Screw Masonry Screw 12 12 INSTALLATION Connecting To Gas Supply INSTALLATION Continued CONNECTING TO GAS SUPPLY WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator. WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. CAUTION: Never connect propane/LP fireplace directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply. WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas. Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figures 16 or 17 page 13, depending on your model). IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas. We recommend that you install a sediment trap in supply line as shown in Figures 16 or 17 page 13, depending on your mode...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories