6. Turn the thermostat/control knob counterclockwise to the .PILOT. position. 7. Use a lit match held securely with an extension device, or a long stem igniter. While holding the ignition source at the pilot, depress the pilot button to light the pilot. 8. Keep pilot button depressed for 60 seconds to properly heat thermocouple and activate safety controls. 9. If pilot does not remain lit, repeat steps 7 & 8. . If the pilot will not stay lit after several attempts, turn the thermostat/control knob to .OFF. and contact your service technician. . If the pilot button does not pop up when released, stop and immediately call your service technician or gas supplier. 10. Once the pilot is established, slide the inner door to the left and replace the outer door. 11. Turn the thermostat control knob counterclockwise to turn on the heater. Set the knob position to the .LOW. marking to start. Adjust the temperature up as required. To Turn Off the Gas Control 1. Rotate the thermostat control knob clockwise to the .OFF. position. SIT GAS CONTROL (TOP VIEW) LIGHTING INSTRUCTIONS FOR HEATER WITH .ROBERTSHAW R110. GA. CONTROL. WARNING. Should overheating occur or the gas supply fail to shut off, turn off the manual gas valve to the appliance. 1. STOP! Read all safety labels on the water heater before operation. 2. Set the thermostat to the lowest setting. Rotate dial on front of control counterclockwise. 3. Rotate gas control knob on top of thermostat clockwise to .OFF. position. 4. Wait 5 minutes to clear out any gas. If you smell gas, STOP! Follow instruction .B. above on page 7. If you do not smell gas, go to the next step. 5. Remove outer door. Slide inner combustion door to right. 6. Find pilot. Follow aluminum tube from the .right-underside. of the gas thermostat. The pilot is adjacent to burner. 7. Turn gas control knob counterclockwise to .PILOT. position. 8. Use a lit match held securely with an extension device, or a long stem igniter. While holding the ignition source at the pilot, depress the red pilot set button (upper left) to light the pilot. Continue to hold the pilot set button for about 1 minute after pilot is lit. Release pilot set button and it will pop up. Pilot should remain lit. .If knob does not pop up when released, stop and immediately call your service technician or gas supplier. .If the pilot will not stay lit after several tries, turn the control knob to .OFF” and call your service technician or gas supplier. To Turn Of. the Gas Contro. 9. Slide inner combustion door to left and replace outer door. 1. Set the thermostat dial to the lowest setting. Turn 10. Turn gas control knob counterclockwise to .ON. position. counterclockwise. 2. Turn gas control knob .OFF.. Rotate clockwise. 11. Set the thermostat to desired setting clockwise. ROBERTSHAW R110 GAS CONTROL LIGHTING INSTRUCTIONS FOR HEATER WITH .ROBERTSHAW 220R.GASCONTROLSWARNING:Should overheating occur or the gas supply fail to shut off, turn off the manual gas valve to the appliance. 1. STOP! Read all safety labels on the water heater before operation. 2. Rotate gas control knob on top of thermostat clockwise to .OFF. position. 3. Set the thermostat to lowest setting. 4. Wait (5) minutes to clear out any gas. If you then smell gas, STOP! Follow instruction .B. above on page 7. If you don.t smell gas, go to the next step. 5. Remove outer door. Slide inner combustion door to right. 6. Find pilot. Follow aluminum tube from the .right-underside. of the gas thermostat. The pilot is adjacent to burner. 7. Turn gas control knob counterclockwise to .PILOT. position. 8. Use a lit match held securely with an extension device, or a long stem igniter. While holding the ignition source at the pilot, depress the gas control knob to light the pilot. 9. After pilot lights, keep knob depressed for at least 60 seconds to properly heat thermocouple and activate safety valves. 10. If the pilot does not remain lit wait at least 10 minutes and repeat steps 1-9. .If knob does not pop up when released, stop and immediately call your service technician or gas supplier. .If the pilot will not stay lit after several tries, turn the control knob to .OFF. and call your service technician or gas supplier. 11. Slide inner combustion door to left and replace outer door. 12. Turn gas control knob counterclockwise to .ON. position. 13. Set thermostat to desired setting clockwise. To Turn Offthe Gas Control1. Set the thermostat dial to the lowest setting. Turn counterclockwise. 2. Turn gas control knob .OFF.. Rotate clockwise. ROBERTSHAW 220R GAS CONTROL TEMPERATURE DIAL SPECIAL NOTE ON PROPANE FUEL. L.P. GAS IS HEAVIER THAN AI. Should there be a leak in the system, the gas will settle at FLOOR LEVEL. Basements, crawl spaces, closets and areas below ground level will serve as pockets for the accumulation of the gas. BEFORE LIGHTING. SNIFF AT FLOOR LEVEL. IF YO. SMELL GAS. FOLLOW THESE RULES. 1. Get all people out of the building. 2. DO NOT light matches. 3. DO NOT touch elec...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - Gas Fired Water Heater (1.61 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories