ft. or less HIGH RECOVERY ► Cuts fuel costs substantially because the standby and radiation losses normal to other boilers and tank-type water heaters are eliminated LOW WATER OPERATING TEMPERATURE ► Operates with water temperature as low as 105°F without condensing Heat Exchanger ■ ASME Inspected and Stamped 160 PSIG ■ National Board Approved ■ Headers □ Cast Iron Glass-lined - Standard □ Bronze - Option A-1 ■ Finned Tubing □ Copper - Standard □ Cupro Nickel - Option A-3 ■ ASME Steel Tube Sheet ■ Silicone O-Rings ■ ASME Pressure Relief Valve □ 45 PSIG - Standard □_PSIG ASME - Optional ■ Temperature and Pressure Gauge, Shipped Loose ■ Water Connections □ Left Hand - Standard □ Right Hand - Option A-6 ■ Flow Configuration - Two-pass ■ Pump - Optional □ Mounted, 1/8 HP, 120 Volt, 10, 60 Hz Controls 120V, 60Hz, 1 Ph Power Supply 120/24V Transformer 100% Pilot Shut-off/Lockout Electronic, Intermittent Ignition (IID) Pilot High Limit Control, Manual Reset On/Off Switch Flow Switch Economaster II Pump Time Delay Gas Control Train ■ Manual Main Gas Shut-off Cock ■ Main Gas Pressure Regulator ■ Redundant Safety Shut-off Valve ■ Control Valve ■ Firing Mode □ On/Off (H4) □ Two-stage Firing (H3) □ Mechanical Modulation, 110-170°F (H5) □ Mechanical Modulation, 150-210°F (H1) ■ Fuel □ Natural Gas □ Propane Gas ■ Design Certified ANSI Z21.13 Construction ■ Front Controls ■ Stainless Steel Burners ■ Polytuf Powder Coat Finish ■ Vent Selection □ Draft Diverter - Option D-10 □ Power Vent, Loose - Option D-2 ■ Base (Optional) □ Combustible Floor Shield -Option J-1 Temperature Controls Note: H1 and H5 do not require a controller □ B-6 Two-stage - 100-200°F □ Y-241 Electronic Sequencer, 1-4 Stages □ Y-281 Electronic Sequencer, 1-8 Stages Additional Safety Controls □ F-10 □ I-1 □ S-1 □ S-2 □ □ Low Water Cut-off Probe High Limit Control, Auto Reset, 240°F Low Gas Pressure Switch, Manual High Gas Pressure Switch, Manual Regulatory Agency Requirements □_ □_ Catalog No.: 2000.205D Effective: 1-1-08 Replaces: 4-1-05 Raytherm - Type H Hydronic Heating Boilers - Indoor Model Dimensions (Inches) Shipping Weight (Lbs.) - Approx. Model No. MBTU Input MBTU Output AFUE* (%) Width A Height C J Flue Dia. K No Pump w/ Pump H-182 181 148 82.6 18-1/4 62-5/8 12-1/16 6 191 221 H-260 264 216 82.7 22-3/8 62-7/8 11-1/8 7 214 244 H-330 334 274 N/A 25-3/4 63-3/4 10-3/4 8 234 264 H-400 399 327 N/A 29-1/4 65-3/8 12-1/2 9 253 283 * With Vent Damper NOTE: Ratings shown are for elevations up to 2,000 feet. For elevations over 2,000, reduce ratings at the rate of 4% for each 1,000 feet above sea level. BOILER RATE OF FLOW AND PRESSURE DROP Model No. 10° AT 20° AT 30° AT GPM AP FT GPM AP FT GPM AP FT H-182 30 4.2 N/A N/A N/A N/A H-260 43 8.5 22 2.2 N/A N/A H-330 N/A N/A 27 3.4 N/A N/A H-400 N/A N/A 33 5.2 22 2.3 N/A - Not Applicable Raypak, Inc. ■ 2151 Eastman Avenue, Oxnard, CA 93030 ■ (805) 278-5300 ■ Fax (800) 872-9725 ■ Catalog No.: 2000.205D Effective: 1-1-08 Replaces: 4-1-05...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories